MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/0972-9941.140210

Медицинская библиотека · Journal of minimal access surgery · 2015

I-gel as an alternative to endotracheal tube in adult laparoscopic surgeries: A comparative study.

Badheka Jigisha Prahladrai, Jadliwala Rashida Mohammedi, Chhaya Vrajeshchandra Amrishbhi, Parmar Vandana Surendrabhai, Vasani Amit, Rajyaguru Ajay Maganlal

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The tracheal tube is always considered to be the gold standard for laparoscopic surgeries. As conventional laryngoscopy guided endotracheal intubation evokes significant hypertension and tachycardia, we have used I-gel, second generation extraglottic airway device, in an attempt to overcome these drawbacks. We conducted this study to compare haemodynamic changes during insertion, efficacy of ventilation, and complications with the use of I-gel when compared with endotracheal tube (ETT) in laparoscopic surgeries.

MATERIALS AND

METHODS

A total of 60 American Society of Anaesthesiologists physical status I and II adult patients undergoing elective laparoscopic surgeries were randomly allocated to one of the two groups of 30 patients each: Group-A (I-gel) in which patients airway was secured with appropriate sized I-gel, and Group-B (ETT) in which patients airway was secured with laryngoscopy - guided endotracheal intubation. Ease, attempts and time for insertion of airway device, haemodynamic and ventilatory parameters at different time intervals, and attempts for gastric tube insertion, and perioperative complications were recorded.

RESULTS

There was significant rise in pulse rate and mean blood pressure during insertion with use of ETT when compared to I-gel. Furthermore, time required for I-gel insertion was significantly less when compared with ETT. However ease and attempts for airway device insertion, attempts for gastric tube insertion and efficacy of ventilation were comparable between two groups.

CONCLUSION

We concluded that I-gel requires less time for insertion with minimal haemodynamic changes when compared to ETT. I-gel also provides adequate positive-pressure ventilation, comparable with ETT. Hence I-gel can be a safe and suitable alternative to ETT for laparoscopic surgeries.

Для цитирования: Badheka Jigisha Prahladrai, Jadliwala Rashida Mohammedi, Chhaya Vrajeshchandra Amrishbhi, Parmar Vandana Surendrabhai, Vasani Amit, Rajyaguru Ajay Maganlal. I-gel as an alternative to endotracheal tube in adult laparoscopic surgeries: A comparative study.. Journal of minimal access surgery. 2015. DOI: 10.4103/0972-9941.140210.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.