Point-of-Care Ultrasound-Guided Protocol to Confirm Central Venous Catheter Placement in Pediatric Patients Undergoing Cardiothoracic Surgery: A Prospective Feasibility Study.

Baehner Torsten, Rohner Marc, Heinze Ingo, Schindler Ehrenfried, Wittmann Maria, Strassberger-Nerschbach Nadine, Kim Se-Chan, Velten Markus

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Central venous catheters (CVC) are commonly required for pediatric congenital cardiac surgeries. The current standard for verification of CVC positioning following perioperative insertion is postsurgical radiography. However, incorrect positioning may induce serious complications, including pleural and pericardial effusion, arrhythmias, valvular damage, or incorrect drug release, and point of care diagnostic may prevent these serious consequences. Furthermore, pediatric patients with congenital heart disease receive various radiological procedures. Although relatively low, radiation exposure accumulates over the lifetime, potentially reaching high carcinogenic values in pediatric patients with chronic disease, and therefore needs to be limited. We hypothesized that correct CVC positioning in pediatric patients can be performed quickly and safely by point-of-care ultrasound diagnostic.

METHODS

We evaluated a point-of-care ultrasound protocol, consistent with the combination of parasternal craniocaudal, parasternal transversal, suprasternal notch, and subcostal probe positions, to verify tip positioning in any of the evaluated views at initial CVC placement in pediatric patients undergoing cardiothoracic surgery for congenital heart disease.

RESULTS

Using the combination of the four views, the CVC tip could be identified and positioned in 25 of 27 examinations (92.6%). Correct positioning was confirmed via chest X-ray after the surgery in all cases.

CONCLUSIONS

In pediatric cardiac patients, point-of-care ultrasound diagnostic may be effective to confirm CVC positioning following initial placement and to reduce radiation exposure.

Для цитирования: Baehner Torsten, Rohner Marc, Heinze Ingo, Schindler Ehrenfried, Wittmann Maria, Strassberger-Nerschbach Nadine, Kim Se-Chan, Velten Markus. Point-of-Care Ultrasound-Guided Protocol to Confirm Central Venous Catheter Placement in Pediatric Patients Undergoing Cardiothoracic Surgery: A Prospective Feasibility Study.. Journal of clinical medicine. 2021. DOI: 10.3390/jcm10245971.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.