European journal of radiology · 2023
Value of pre-/post-contrast-enhanced T1 mapping and readout segmentation of long variable echo-train diffusion-weighted imaging in differentiating parotid gland tumors.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Wen Baohong, Zhang Zanxia, Fu Kun, Zhu Jing, Liu Liang, Gao Eryuan, Qi Jinbo, Zhang Yong, Cheng Jingliang, Qu Feifei, Zhu Jinxia
Аннотация
PURPOSE: This study aimed to explore the value of pre-/post-contrast-enhanced T1 mapping and readout segmentation of long variable echo-train diffusion-weighted imaging (RESOLVE-DWI) for the differential diagnosis of parotid gland tumors.
METHODS: A total of 128 patients with histopathologically confirmed parotid gland tumors [86 benign tumors (BTs) and 42 malignant tumors (MTs)] were retrospectively recruited. BTs were further divided into pleomorphic adenomas (PAs, n = 57) and Warthin's tumors (WTs, n = 15). MRI examinations were performed before and after contrast injection to measure the longitudinal relaxation time (T1) value (T1p and T1e, respectively) and the apparent diffusion coefficient (ADC) value of the parotid gland tumors. The reduction in T1 (T1d) values and the percentage of T1 reduction (T1d%) were calculated.
RESULTS: The T1d and ADC values of the BTs were considerably higher than those of the MTs (all P <.05). The area under the curve (AUC) of the T1d and ADC values for differentiating between BTs and MTs of the parotid was 0.618 and 0.804, respectively (all P <.05). The AUC of the T1p, T1d, T1d%, and ADC values for differentiating between PAs and WTs was 0.926, 0.945, 0.925, and 0.996, respectively (all P >.05). The ADC and T1d% + ADC values performed better in differentiating between PAs and MTs than the T1p, T1d, and T1d% (AUC values: 0.902, 0.909, 0.660, 0.726, and 0.736, respectively). The T1p, T1d, T1d%, and T1d% + T1p values all had high diagnosis efficacy in differentiating WTs from MTs (AUC values: 0.865, 0.890, 0.852, and 0.897, respectively, all P >.05).
CONCLUSION: T1 mapping and RESOLVE-DWI can be used to differentiate parotid gland tumors quantitatively and can be complementary to each other.
METHODS: A total of 128 patients with histopathologically confirmed parotid gland tumors [86 benign tumors (BTs) and 42 malignant tumors (MTs)] were retrospectively recruited. BTs were further divided into pleomorphic adenomas (PAs, n = 57) and Warthin's tumors (WTs, n = 15). MRI examinations were performed before and after contrast injection to measure the longitudinal relaxation time (T1) value (T1p and T1e, respectively) and the apparent diffusion coefficient (ADC) value of the parotid gland tumors. The reduction in T1 (T1d) values and the percentage of T1 reduction (T1d%) were calculated.
RESULTS: The T1d and ADC values of the BTs were considerably higher than those of the MTs (all P <.05). The area under the curve (AUC) of the T1d and ADC values for differentiating between BTs and MTs of the parotid was 0.618 and 0.804, respectively (all P <.05). The AUC of the T1p, T1d, T1d%, and ADC values for differentiating between PAs and WTs was 0.926, 0.945, 0.925, and 0.996, respectively (all P >.05). The ADC and T1d% + ADC values performed better in differentiating between PAs and MTs than the T1p, T1d, and T1d% (AUC values: 0.902, 0.909, 0.660, 0.726, and 0.736, respectively). The T1p, T1d, T1d%, and T1d% + T1p values all had high diagnosis efficacy in differentiating WTs from MTs (AUC values: 0.865, 0.890, 0.852, and 0.897, respectively, all P >.05).
CONCLUSION: T1 mapping and RESOLVE-DWI can be used to differentiate parotid gland tumors quantitatively and can be complementary to each other.