Comparison of methods for the analysis of airway macrophage particulate load from induced sputum, a potential biomarker of air pollution exposure.
Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Jary Hannah, Rylance Jamie, Patel Latifa, Gordon Stephen B, Mortimer Kevin
Аннотация
BACKGROUND: Air pollution is associated with a high burden or morbidity and mortality, but exposure cannot be quantified rapidly or cheaply. The particulate burden of macrophages from induced sputum may provide a biomarker. We compare the feasibility of two methods for digital quantification of airway macrophage particulate load.
METHODS: Induced sputum samples were processed and analysed using ImageJ and Image SXM software packages. We compare each package by resources and time required.
RESULTS: 13 adequate samples were obtained from 21 patients. Median particulate load was 0.38 μm(2) (ImageJ) and 4.0 % of the total cellular area of macrophages (Image SXM), with no correlation between results obtained using the two methods (correlation coefficient = -0.42, p = 0.256). Image SXM took longer than ImageJ (median 26 vs 54 mins per participant, p = 0.008) and was less accurate based on visual assessment of the output images. ImageJ's method is subjective and requires well-trained staff.
CONCLUSION: Induced sputum has limited application as a screening tool due to the resources required. Limitations of both methods compared here were found: the heterogeneity of induced sputum appearances makes automated image analysis challenging. Further work should refine methodologies and assess inter- and intra-observer reliability, if these methods are to be developed for investigating the relationship of particulate and inflammatory response in the macrophage.
METHODS: Induced sputum samples were processed and analysed using ImageJ and Image SXM software packages. We compare each package by resources and time required.
RESULTS: 13 adequate samples were obtained from 21 patients. Median particulate load was 0.38 μm(2) (ImageJ) and 4.0 % of the total cellular area of macrophages (Image SXM), with no correlation between results obtained using the two methods (correlation coefficient = -0.42, p = 0.256). Image SXM took longer than ImageJ (median 26 vs 54 mins per participant, p = 0.008) and was less accurate based on visual assessment of the output images. ImageJ's method is subjective and requires well-trained staff.
CONCLUSION: Induced sputum has limited application as a screening tool due to the resources required. Limitations of both methods compared here were found: the heterogeneity of induced sputum appearances makes automated image analysis challenging. Further work should refine methodologies and assess inter- and intra-observer reliability, if these methods are to be developed for investigating the relationship of particulate and inflammatory response in the macrophage.