MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jinf.2024.106301

Медицинская библиотека · The Journal of infection · 2024

Occurrence and predictors of laboratory abnormalities during outpatient parenteral antimicrobial therapy - A multicenter cohort study to inform laboratory test monitoring.

Stoorvogel Hester H, van Egmond Maartje, Wertheim Heiman F L, Schouten Jeroen A, Hulscher Marlies E J L, Peeters Lars, Kiers Yvonne, Koenders Sofie, Sprong Tom, van Mens Suzan P, Tromp Mirjam, Richel Olivier, Akkermans Reinier, Ten Oever Jaap

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

Evidence on the optimal frequency of laboratory testing during outpatient parenteral antimicrobial therapy (OPAT) is lacking. Therefore, we investigated how often and when laboratory abnormalities occur during OPAT and which factors are associated with these abnormalities.

METHODS

We performed a multicenter cohort study in four Dutch hospitals among adult patients receiving OPAT and collected routinely obtained laboratory test results. Incidence and incidence rates were calculated for various laboratory abnormalities. Survival analysis was performed to visualize the time to the first occurrence of laboratory abnormalities and Poisson regression analysis to compare the number of abnormalities in the first and second 30 OPAT days among patients receiving OPAT for ≥60 days. Predictors were identified using a multivariable Cox proportional hazard regression model.

RESULTS

45.1% of 1152 included patients developed laboratory abnormalities, but only 2% led to OPAT discontinuation. Hepatotoxicity was most common (33.9 events/1000 OPAT days), with a time-dependent decrease in the occurrence of the first hepatotoxic event, while hypokalemia was rare (1.7 events/1000 OPAT days). In the subgroup of patients receiving ≥60 days of OPAT, nephrotoxicity was more common in days 31-60. We observed partly toxicity-specific associations between antibiotic type, concomitant medication, baseline laboratory values, patient characteristics, and the occurrence of laboratory abnormalities.

CONCLUSIONS

While laboratory abnormalities are frequently observed during OPAT, they rarely lead to discontinuation of OPAT. Specific patient, treatment and laboratory characteristics were associated with the occurrence of laboratory abnormalities. Based on our results, we recommend a more personalized laboratory monitoring policy with less blood sampling.

Для цитирования: Stoorvogel Hester H, van Egmond Maartje, Wertheim Heiman F L, Schouten Jeroen A, Hulscher Marlies E J L, Peeters Lars, Kiers Yvonne, Koenders Sofie, Sprong Tom, van Mens Suzan P, Tromp Mirjam, Richel Olivier, Akkermans Reinier, Ten Oever Jaap. Occurrence and predictors of laboratory abnormalities during outpatient parenteral antimicrobial therapy - A multicenter cohort study to inform laboratory test monitoring.. The Journal of infection. 2024. DOI: 10.1016/j.jinf.2024.106301.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.