DOI 10.1111/apa.17268

Медицинская библиотека · Acta paediatrica (Oslo, Norway : 1992) · 2024

Effects of automatic heel lancet on invasiveness in neonates: A systematic review and meta-analysis.

Shiroshita Yui, Yonezawa Kaori, Ota Erika, Ozawa Mio

СтатьяСистематический обзорМетаанализПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIM: We conducted a meta-analysis comparing the invasiveness of automatic lancet devices, which can collect adequate amount of blood at shallow puncture depths, with conventional manual lance devices (lancet or needle) to statistically identify less invasive instruments for neonatal heel lance.

METHODS

We searched PubMed, Cochrane Central Register of Controlled Trials (CENTRAL), CINAHL, and Ichushi databases for studies comparing the invasiveness between automatic lancet and manual lancet or needle in term and preterm neonates in neonatal intensive care unit.

RESULTS

This review included 9 out of 449 searched articles, with 673 neonates. Automatic lancet had significantly lower pain scores (standardised mean difference: -2.0, 95% confidence interval: -3.3 to -0.7), heart rate (mean difference: -8.0, 95% confidence interval: -13.8 to -2.1), cry duration (mean difference: -21.5, 95% confidence interval: -32.5 to -10.4), number of punctures (mean difference: -0.6, 95% confidence interval: -1.1 to -0.2), and duration of procedures (mean difference: -37.7, 95% confidence interval: -75.2 to -0.2) than manual lancet or needle. Furthermore, peripheral oxygen saturation was significantly higher in automatic lancet than in manual lancet or needle (mean difference: 4.5, 95% confidence interval: 0.5-8.5).

CONCLUSION

Automatic heel lancet devices were less invasive than manual heel lance devices (lancet or needle).

Для цитирования: Shiroshita Yui, Yonezawa Kaori, Ota Erika, Ozawa Mio. Effects of automatic heel lancet on invasiveness in neonates: A systematic review and meta-analysis.. Acta paediatrica (Oslo, Norway : 1992). 2024. DOI: 10.1111/apa.17268.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.