MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcjo.2024.07.012

Медицинская библиотека · Canadian journal of ophthalmology. Journal canadien d'ophtalmologie · 2024

Comparison of venturi and peristaltic based phacoemulsification efficiency in routine femtosecond laser cataract surgery.

Scott Rachel A, Holtmeyer Caleb J, Parker Travis M, Scott Wendell J, Olson Randall J

СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare the efficiency of venturi and peristaltic pump phacoemulsification systems in patients undergoing routine laser cataract surgery.

DESIGN

Single center, nonrandomized clinical study.

PARTICIPANTS

The study compared consecutive eyes with moderate nuclear sclerosis undergoing routine laser cataract surgery at the Outpatient Eye Center, Mercy Health System, Springfield, MO, USA.

METHODS

Each surgery used the same femtosecond laser settings. Surgeries were performed with either a venturi or peristaltic vacuum system by a single surgeon (WJS). The EFX, percent power, ultrasound time (UST), the total time that the phaco tip was in the eye (phaco tip in/out time, PIOT), and the surgery time (speculum in/out time) were recorded. Exclusions and intraoperative complications were also analyzed.

RESULTS

995 eyes were included in the study. The EFX in the venturi eyes (1.7 ± 1.3; n = 521) compared to peristaltic eyes (2.1 ± 1.4; n = 474) was lower (p < 0.0001). Similarly, the UST in the eyes performed with the venturi system versus the peristaltic system was reduced (32.4 ± 22.3 s vs 40.7± 25.7 s; p < 0.0001). The PIOT in the venturi group compared to the peristaltic group was less (71.1 ± 31.1 sec vs 79.1 ± 36.1 s; p = 0.0002). The case time (speculum in/out time) was lower for the venturi eyes (307.2 ± 68.8 s vs. 311.6 ± 53.6 s; p = 0.268).

CONCLUSION

In eyes undergoing routine laser cataract surgery, the use of the venturi pump system was more efficient compared to the peristaltic pump system based on energy use and time, and there was no significant difference in complications.

Для цитирования: Scott Rachel A, Holtmeyer Caleb J, Parker Travis M, Scott Wendell J, Olson Randall J. Comparison of venturi and peristaltic based phacoemulsification efficiency in routine femtosecond laser cataract surgery.. Canadian journal of ophthalmology. Journal canadien d'ophtalmologie. 2024. DOI: 10.1016/j.jcjo.2024.07.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.