MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/978-1-4939-8678-1_3

Медицинская библиотека · Methods in molecular biology (Clifton, N.J.) · 2018

Influenza A Virus Genetic Tools: From Clinical Sample to Molecular Clone.

Anchisi Stéphanie, Gonçalves Ana Rita, Mazel-Sanchez Béryl, Cordey Samuel, Schmolke Mirco

СтатьяПеревод пока не подготовлен

Аннотация

Implementation of reverse genetics for influenza A virus, that is, the DNA-based generation of infectious viral particles in cell culture, opened new avenues to investigate the function of viral proteins and their interplay with host factors on a molecular level. This powerful technique allows the introduction, depletion, or manipulation of any given sequence in the viral genome, as long as it gives rise to replicating virus progeny. Reverse genetics can be used to generate targeted reassortant viruses by mixing segments of different viral strains, thus providing insight into phenotypes of potentially pandemic viruses arising from natural reassortment. It was further instrumental for the development of novel vaccine strategies, allowing rapid and targeted exchange of viral surface antigens on a well-replicating genetic backbone of cell culture-adapted or cold-adapted/attenuated viral strains. Establishment of reverse genetics and rescue of molecular clones of influenza A virus have been extensively described before. Here we give a detailed stand-alone protocol encompassing clinical sampling of influenza A virus specimens and subsequent plasmid-based genetics to rescue, manipulate, and confirm a fully infectious molecular clone. This protocol is based on the combined techniques and experience of a number of influenza laboratories, which are credited and referenced whenever appropriate.

Для цитирования: Anchisi Stéphanie, Gonçalves Ana Rita, Mazel-Sanchez Béryl, Cordey Samuel, Schmolke Mirco. Influenza A Virus Genetic Tools: From Clinical Sample to Molecular Clone.. Methods in molecular biology (Clifton, N.J.). 2018. DOI: 10.1007/978-1-4939-8678-1_3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.