MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajic.2018.02.018

Медицинская библиотека · American journal of infection control · 2018

Ultraviolet germicidal irradiation of influenza-contaminated N95 filtering facepiece respirators.

Mills Devin, Harnish Delbert A, Lawrence Caryn, Sandoval-Powers Megan, Heimbuch Brian K

Оценочное исследованиеСтатьяПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Safe and effective decontamination and reuse of N95 filtering facepiece respirators (FFRs) has the potential to significantly extend FFR holdings, mitigating a potential shortage due to an influenza pandemic or other pandemic events. Ultraviolet germicidal irradiation (UVGI) has been shown to be effective for decontaminating influenza-contaminated FFRs. This study aims to build on past research by evaluating the UVGI decontamination efficiency of influenza-contaminated FFRs in the presence of soiling agents using an optimized UVGI dose.

METHODS

Twelve samples each of 15 N95 FFR models were contaminated with H1N1 influenza (facepiece and strap), then covered with a soiling agent-artificial saliva or artificial skin oil. For each soiling agent, 3 contaminated FFRs were treated with 1 J/cm2 UVGI for approximately 1 minute, whereas 3 other contaminated FFRs remained untreated. All contaminated surfaces were cut out and virus extracted. Viable influenza was quantified using a median tissue culture infectious dose assay.

RESULTS

Significant reductions (≥3 log) in influenza viability for both soiling conditions were observed on facepieces from 12 of 15 FFR models and straps from 7 of 15 FFR models.

CONCLUSIONS

These data suggest that FFR decontamination and reuse using UVGI can be effective. Implementation of a UVGI method will require careful consideration of FFR model, material type, and design.

Для цитирования: Mills Devin, Harnish Delbert A, Lawrence Caryn, Sandoval-Powers Megan, Heimbuch Brian K. Ultraviolet germicidal irradiation of influenza-contaminated N95 filtering facepiece respirators.. American journal of infection control. 2018. DOI: 10.1016/j.ajic.2018.02.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.