MedElevator Войти в исследования
← Поиск публикаций

DOI 10.64898/2026.04.02.716213

Медицинская библиотека · bioRxiv : the preprint server for biology · 2026

Tm-guided exon-exon junction RT-PCR enables specific detection of RNA variants lacking easily distinguishable exonic regions.

Ahn Junyeop, Zack Donald J, Zhang Ping-Wu

СтатьяПрепринтПеревод пока не подготовлен

Аннотация

Accurate detection of RNA splice variants is often hindered when transcripts lack large distinguishable exonic regions, making conventional PCR strategies challenging. We developed a simple melting temperature (Tm)-guided exon-exon junction (EEJ) RT-PCR method to enable variant-specific detection under these conditions. Uni-directional primers spanning exon-exon junctions were designed so that approximately each half anneals to adjacent exons. The Tm of each half-site was set >7°C below the annealing temperature, preventing stable binding to individual exons and enforcing junction-dependent amplification. The method was evaluated using HTRA1-AS1 long noncoding RNA variants that share overlapping exon sequences but differ in splice connectivity. HTRA1-AS1 comprises five variants, only one with a large distinguishable exon. Tm-guided EEJ primers robustly discriminated the remaining four variants. After optimization, amplification yielded sharp, single bands with minimal cross-reactivity. Compared with conventional designs, this approach reduced heteroduplex and heteroquadruplex formation, improving band clarity. Sanger sequencing confirmed junction specificity, and the method performed well in multiplex settings. Overall, Tm-guided EEJ RT-PCR is a cost-effective, high-resolution approach for detecting RNA variants lacking easily distinguishable exonic regions, readily compatible with standard RT-PCR and qPCR workflows.

Для цитирования: Ahn Junyeop, Zack Donald J, Zhang Ping-Wu. Tm-guided exon-exon junction RT-PCR enables specific detection of RNA variants lacking easily distinguishable exonic regions.. bioRxiv : the preprint server for biology. 2026. DOI: 10.64898/2026.04.02.716213.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.