MedElevator Войти в исследования
← Поиск публикаций

DOI 10.55460/sopz-stap

Медицинская библиотека · Journal of special operations medicine : a peer reviewed journal for SOF medical professionals · 2020

US Army Combat Medic Performance With Portable Ultrasound to Detect Sonographic Findings of Pneumothorax in a Cadaveric Model.

Meadows Robert M, Monti Jonathan D, Umar Mohamad A, Van Arnem Kerri A, Chin Eric J, Mitchell Christopher A, Love Sue

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Ultrasound, due to recent advances in portability and versatility, has become a valuable clinical adjunct in austere, resource-limited settings and is well demonstrated to be an accurate/efficient means to detect pneumothorax. The purpose of this study was to evaluate the impact of hands-on ultrasound training on ultrasound-naive US Army combat medics' ability to detect sonographic findings of pneumothorax with portable ultrasound in a cadaver model.

METHODS

Ultrasound-naive US Army combat medics assigned to conventional military units were recruited from a single US Army installation and randomized to receive either didactic training only, or "blended" (didactic and hands-on) training on ultrasound detection of pneumothorax. Blinded participants were asked to perform a thoracic ultrasound exam on ventilated human cadaver models. Primary outcome measured was sensitivity and specificity of detecting sonographic findings of pneumothorax between cohorts.

RESULTS

Forty-three participants examined a total of 258 hemithoraces. The didactic-only cohort (n = 24) detected sonographic findings of pneumothorax with a sensitivity of 68% and specificity of 57%. The blended cohort (n = 19) detected sonographic findings of pneumothorax with an overall sensitivity of 91% and specificity of 80%. Detection sensitivities were similar between B-mode versus M-mode use.

CONCLUSION

US Army combat medics can use portable U/S to detect sonographic findings of pneumothorax in a human cadaver model with high sensitivity after a brief, blended (didactic and hands-on) training intervention.

Для цитирования: Meadows Robert M, Monti Jonathan D, Umar Mohamad A, Van Arnem Kerri A, Chin Eric J, Mitchell Christopher A, Love Sue. US Army Combat Medic Performance With Portable Ultrasound to Detect Sonographic Findings of Pneumothorax in a Cadaveric Model.. Journal of special operations medicine : a peer reviewed journal for SOF medical professionals. 2020. DOI: 10.55460/sopz-stap.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.