MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvir.2020.04.028

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2020

Methylene Blue/Collagen Mixture for CT-Guided Presurgical Lung Nodule Marking: High Efficacy and Safety.

Aoun Hussein D, Littrup Peter J, Heath Katherine E, Adam Barbara, Prus Matt, Beydoun Rafic, Baciewcz Frank

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess outcomes of computed tomography (CT)-guided methylene blue/collagen marking of preoperative lung nodules before video-assisted thoracoscopic surgery (VATS) and robotic-assisted thoracic surgery (RATS).

MATERIALS AND

METHODS

A retrospective cohort study assessing 25 methylene blue/collagen solution CT-guided lung nodule localization procedures on 26 nodules in 25 patients was performed. The procedures were performed by a fellowship-trained radiologist 1-2 hours before scheduled surgery under local anesthesia. Approximately 4-6 ml of methylene blue/collagen solution was injected in a perinodular location under CT guidance with a 19-gauge trocar needle and along the track to the visceral pleural surface. Post-procedural CT images confirmed appropriate lung nodule location marking.

RESULTS

Perinodular CT-guided trocar needle placement was achieved in all marking procedures (n = 26/26). Increased consolidation near the target nodule was also demonstrated in all patients on the post-procedural localized CT scans. One patient with moderate emphysema developed a small to moderate-sized pneumothorax (∼20%-30%), and an 8-Fr thoracentesis catheter was placed under CT guidance before surgery. There was no bleeding or hemoptysis in any patient. Methylene blue/collagen solution was readily visible by the thoracic surgeon in association with all target nodules. One patient required conversion to open procedure due to the proximal portion of the right lower lobe pulmonary artery segmental branch. Of the 26 identified nodules, pathology specimens confirmed the adequacy of nodule resection in all cases.

CONCLUSIONS

Preoperative CT-guided methylene blue/collagen solution injection offers a safe and highly effective technique for marking subpleural lung nodules undergoing VATS or RATS.

Для цитирования: Aoun Hussein D, Littrup Peter J, Heath Katherine E, Adam Barbara, Prus Matt, Beydoun Rafic, Baciewcz Frank. Methylene Blue/Collagen Mixture for CT-Guided Presurgical Lung Nodule Marking: High Efficacy and Safety.. Journal of vascular and interventional radiology : JVIR. 2020. DOI: 10.1016/j.jvir.2020.04.028.