MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/rapm-2020-101402

Медицинская библиотека · Regional anesthesia and pain medicine · 2020

Complication rate of ultrasound-guided paravertebral block for breast surgery.

Niesen Adam D, Jacob Adam K, Law Luke A, Sviggum Hans P, Johnson Rebecca L

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVES

Thoracic paravertebral blockade is often used as an anesthetic and/or analgesic technique for breast surgery. With ultrasound guidance, the rate of complications is speculated to be lower than when using landmark-based techniques. This investigation aimed to quantify the incidence of pleural puncture and pneumothorax following non-continuous ultrasound-guided thoracic paravertebral blockade for breast surgery.

METHODS

Patients who received thoracic paravertebral blockade for breast surgery were identified by retrospective query of our institution's electronic database over a 5-year period. Data collected included patient demographics, level of block, type and volume of local anesthetic, occurrence of pleural puncture, occurrence of pneumothorax, evidence of local anesthetic toxicity, and patient vital signs. The incidence of block complications, including pleural puncture, pneumothorax, and local anesthetic toxicity, were ascertained.

RESULTS

529 patients underwent 2163 thoracic paravertebral injections. Zero pleural punctures were identified during block performance; however, two patients were found to have a pneumothorax on postoperative chest X-ray (3.6 per 1000 surgeries, 95% CI 0.5 to 13.6; 0.9 per 1000 levels blocked, 95% CI 0.1 to 3.3). There were no cases of local anesthetic systemic toxicity or associated lipid emulsion therapy administration.

CONCLUSIONS

Pneumothorax following non-continuous ultrasound-guided thoracic paravertebral block using a parasagittal approach is an uncommon occurrence, with a similar rate to pneumothorax following breast surgery alone.

Для цитирования: Niesen Adam D, Jacob Adam K, Law Luke A, Sviggum Hans P, Johnson Rebecca L. Complication rate of ultrasound-guided paravertebral block for breast surgery.. Regional anesthesia and pain medicine. 2020. DOI: 10.1136/rapm-2020-101402.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.