MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jvim.15987

Медицинская библиотека · Journal of veterinary internal medicine · 2020

Interobserver and intraobserver reliability for 2 grading systems for gastric ulcer syndrome in horses.

Wise Jessica C, Wilkes Edwina J A, Raidal Sharanne L, Xie Gang, Crosby Danielle E, Hale Josephine N, Hughes Kristopher J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Grading of equine gastric ulcer syndrome (EGUS) is undertaken in clinical and research settings, but the reliability of EGUS grading systems is poorly understood.

HYPOTHESIS/

OBJECTIVES

Investigate interobserver and intraobserver reliability of an established ordinal grading system and a novel visual analog scale (VAS), and assess the influence of observer experience.

ANIMALS: Sixty deidentified gastroscopy videos.

METHODS

Six observers (3 specialists and 3 residents) graded videos using the EGUS Council (EGUC) system and VAS. Observers graded the videos three 3 for each system, using a cross-over design with at least 1 week between each phase. The order of videos was randomized for each phase.

METHODS

Interobserver and intraobserver reliability were estimated using Gwet's agreement coefficient with ordinal weights applied (AC2) for the EGUC system and the intraclass correlation coefficient (ICC) for the VAS.

RESULTS

Using the EGUC system, interobserver reliability was substantial for squamous (AC2 = 0.69; 95% confidence interval [CI], 0.57-0.80) and glandular mucosa (AC2 = 0.72; 95% CI, 0.70-0.75), and intraobserver reliability was substantial for squamous (AC2 = 0.80; 95% CI, 0.71-0.90) and glandular mucosa (AC2 = 0.80; 95% CI, 0.74-0.86). Interobserver reliability using the VAS was moderate for squamous (ICC = 0.64; 95% CI, 0.31-0.96) and poor for glandular mucosa (ICC = 0.35; 95% CI, 0.06-0.64), and intraobserver reliability was moderate for squamous (ICC = 0.74; 95% CI, 0.62-0.86) and glandular mucosa (ICC = 0.56; 95% CI, 0.39-0.72).

CONCLUSIONS AND CLINICAL

IMPORTANCE

The EGUC system had acceptable intraobserver and interobserver reliability and performed well regardless of observer experience. Familiarity and observer experience improved reliability of the VAS.

Для цитирования: Wise Jessica C, Wilkes Edwina J A, Raidal Sharanne L, Xie Gang, Crosby Danielle E, Hale Josephine N, Hughes Kristopher J. Interobserver and intraobserver reliability for 2 grading systems for gastric ulcer syndrome in horses.. Journal of veterinary internal medicine. 2020. DOI: 10.1111/jvim.15987.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.