Can the Computed Tomographic Aspect of Porto-Systemic Circulation in Cirrhotic Patients be Associated with the Presence of Variceal Hemorrhage?
Аннотация
Background and objectives: Variceal bleeding is a serious complication caused by portal hypertension, frequently encountered among cirrhotic patients. The purpose of this study was to determine whether the aspect of the collateral, porto-systemic circulation, as detected by CT are associated with the presence variceal hemorrhage (VH). Materials and
Methods
81 cirrhotic patients who underwent a contrast-enhanced CT examination were retrospectively included in the study. Patients were divided into two groups: Cirrhotic patients with variceal hemorrhage during the hospital admission concomitant, with the CT examination (n = 33) and group 2-cirrhotic patients, without any variceal hemorrhage in their medical history (n = 48). The diameter of the left gastric vein, the presence or absence and dimensions of oesophageal and gastric varices, paraumbilical veins and splenorenal shunts were the indicators assessed on CT.
Results
The univariate analysis showed a significant association between the presence of upper GI bleeding and the diameters of paraoesophageal veins, paragastric veins and left gastric vein respectively, all of these CT parameters being higher in patients with variceal bleeding. In the multivariate logistic regression analysis, only the diameter of the left gastric vein was independently associated with the presence of variceal hemorrhage (OR = 1.6 (95% CI: 1.17-2.19), p = 0.003). We found an optimal cut-off value of 3 mm for the diameter of the left gastric vein useful to discriminate among patients with variceal hemorrhage from the ones without it, with a good diagnostic performance (AUC = 0.78, Se = 97%, Sp = 45.8%, PPV = 55.2%, NPV = 95.7%).
Conclusions
Our observations point out that an objective CT quantification of porto-systemic circulation can be correlated with the presence of variceal hemorrhage and the diameter of the left gastric vein can be a reliable parameter associated with this condition.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.