MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3346/jkms.2025.40.e236

Медицинская библиотека · Journal of Korean medical science · 2025

A Novel Mouse Model of Mixed Dementia Using Chronic Cerebral Hypoperfusion Induced by Bilateral Carotid Artery Stenosis.

Kim Jang Hun, Kang Ho-Young, Park Sung Young, Yang Yoo Mi, Jo Sang-Kyung, Geum Dongho, Kim Jong-Hoon, Park Dong-Hyuk

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Alzheimer's disease (AD) and vascular dementia (VaD) have distinct pathognomonic features, but they frequently co-occur as mixed dementia (MD) in elderly adults. This study aimed to develop a novel MD mouse model using bilateral carotid artery stenosis (BCAS) in 5 times familial Alzheimer's disease (5xFAD) transgenic mice and characterize its behavioral and histological features.

METHODS

Thirteen C57BL/6 and sixteen 5xFAD transgenic mice were prepared. Six C57BL/6 and seven 5xFAD transgenic mice underwent BCAS surgery, and all mice were housed for 3 months. Mice were divided into wild-type (n = 7), VaD (n = 6), AD (n = 9), and MD (n = 7) groups. Neurobehavioral tests, including the Y-maze test (YMT) and passive avoidance test (PAT), along with immunohistochemical analysis of amyloid β plaque (6E10) and myelin basic protein, were performed.

RESULTS

MD mice exhibited similar deficits in YMT as AD and VaD groups but had significantly worse performance in PAT compared to all other groups. Histologically, MD mice showed amyloid-β accumulation in the cortex/hippocampus and axonal degeneration in the corpus callosum.

CONCLUSION

This novel MD model demonstrates key features of both AD and VaD, providing a valuable tool for studying the pathophysiology of mixed dementia and testing potential therapeutic interventions.

Для цитирования: Kim Jang Hun, Kang Ho-Young, Park Sung Young, Yang Yoo Mi, Jo Sang-Kyung, Geum Dongho, Kim Jong-Hoon, Park Dong-Hyuk. A Novel Mouse Model of Mixed Dementia Using Chronic Cerebral Hypoperfusion Induced by Bilateral Carotid Artery Stenosis.. Journal of Korean medical science. 2025. DOI: 10.3346/jkms.2025.40.e236.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.