MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/01.tp.0000228236.55419.33

Медицинская библиотека · Transplantation · 2007

Telemetric monitoring of pulmonary function after allogeneic hematopoietic stem cell transplantation.

Guihot Amélie, Becquemin Marie-Hélène, Couderc Louis-Jean, Randrianarivelo Odile, Rivaud Elisabeth, Philippe Bruno, Sutton Laurent, Neveu Hélène, Tanguy Marie-Laure, Vernant Jean-Paul, Dhédin Nathalie

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Late-onset noninfectious pulmonary complications (LONIPC) are both frequent and severe after allogeneic hematopoietic stem cell transplantation (HSCT). The high mortality rate (40-80%) may be related to delayed diagnosis. We assessed the use of telemetric home surveillance of pulmonary function for early diagnosis of LONIPC in transplant recipients.

METHODS

This prospective study monitored pulmonary function in 37 allogeneic HSCT recipients. About 3 months after HSCT, they received a portable spirometer that measured forced vital capacity, forced expiratory volume per second, and midexpiratory flow 25-75 (MEF25-75). Data were transmitted twice weekly by telephone. Conventional plethysmography confirmed any significant deterioration (>20%).

RESULTS

Thirteen episodes of spirometric deterioration were detected by telemetry in 11 patients during a median 17-month (4-41) follow-up period after transplantation. In these cases, examinations including spirometry, high-resolution thoracic computed tomography and bronchoalveolar lavage diagnosed LONIPC in eight episodes in seven patients (cumulative incidence 23.4%, SE 0.08, at month 24 after transplant): bronchiolitis obliterans (BO, n=3), interstitial pneumonia (IP, n=4), or both BO and IP (n=1). Five episodes improved and three were stabilized with increased immunosuppressive therapy. At the last follow-up, of the seven patients with LONIPC, one successfully stopped immunosuppressive therapy, two were receiving low-dose mycophenolate mofetil, and four were receiving low-dose corticosteroid therapy. There were no cases of respiratory failure and no patient died from LONIPC.

CONCLUSION

Telemetric home monitoring of pulmonary function is a useful procedure for early diagnosis of LONIPC before clinical pulmonary symptoms and may improve outcome after allogeneic HSCT.

Для цитирования: Guihot Amélie, Becquemin Marie-Hélène, Couderc Louis-Jean, Randrianarivelo Odile, Rivaud Elisabeth, Philippe Bruno, Sutton Laurent, Neveu Hélène, Tanguy Marie-Laure, Vernant Jean-Paul, Dhédin Nathalie. Telemetric monitoring of pulmonary function after allogeneic hematopoietic stem cell transplantation.. Transplantation. 2007. DOI: 10.1097/01.tp.0000228236.55419.33.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.