DOI 10.1136/bmjhci-2020-100310
Smartphone-based remote monitoring of vision in macular disease enables early detection of worsening pathology and need for intravitreal therapy.
Аннотация
BACKGROUND/AIMS: To assess the outcomes of home monitoring of distortion caused by macular diseases using a smartphone-based application (app), and to examine them with hospital-based assessments of visual acuity (VA), optical coherence tomography-derived central macular thickness (CMT) and the requirement of intravitreal injection therapy.
DESIGN
Observational study with retrospective analysis of data.
METHODS
Participants were trained in the correct use of the app (Alleye, Oculocare, Zurich, Switzerland) in person or by using video and telephone consultations. Automated threshold-based alerts were communicated based on a traffic light system. A 'threshold alarm' was defined as three consecutive 'red' scores, and turned into a 'persistent alarm' if present for greater than a 7-day period. Changes of VA and CMT, and the requirement for intravitreal therapy after an alarm were examined.
RESULTS
245 patients performing a total of 11 592 tests (mean 46.9 tests per user) were included and 85 eyes (164 alarms) examined. Mean drop in VA from baseline was -4.23 letters (95% CI: -6.24 to -2.22; p<0.001) and mean increase in CMT was 29.5 µm (95% CI: -0.08 to 59.13; p=0.051). Sixty-six eyes (78.5%) producing alarms either had a drop in VA, increase in CMT or both and 60.0% received an injection. Eyes with persistent alarms had a greater loss of VA, -4.79 letters (95% CI: -6.73 to -2.85; p<0.001) or greater increase in CMT, +87.8 µm (95% CI: 5.2 to 170.4; p=0.038).
CONCLUSION
Smartphone-based self-tests for macular disease may serve as reliable indicators for the worsening of pathology and the need for treatment.