m+Medelevator.RU
← Поиск публикаций
The Tohoku journal of experimental medicine · 2024

Non-Contrast Enhanced MR Angiography in Pre-Procedural Assessment of Aortic Annulus for Transcatheter Aortic Valve Replacement.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sato Takehiro, Miyasaka Masaki, Tada Norio, Kobayashi Tomoya, Sakurai Mie, Kasahara Shinji, Suzuki Shinichi, Taguri Masataka, Machida Yoshio, Ueda Takuya

Аннотация

The purpose of this retrospective study is to investigate the feasibility of measurement of aortic annular size using a respiratory and non-contrast magnetic resonance angiography (MRA) in comparison to those of computed tomography angiography (CTA) in an unselected, consecutive cohort of patients evaluated for transcatheter aortic valve replacement (TAVR). Of 295 consecutive patients (mean age 83.0 ± 4.5 years) with severe aortic stenosis, 68 underwent pre-TAVR CTA and a non-contrast balanced steady-state free precession MRA at 1.5 T. This study evaluated potential discrepancies in preoperative assessments of TAVR device size selection determined by CTA and MRA, and compared with paravalvular aortic valve regurgitation (PAR). The aortic annulus area (AAA) and perimeter (AAP) measured with systolic MRA showed a higher correlation to systolic CTA than those measured with diastolic MRA: intraclass correlation coefficient (ICC) with 95% concordance index (CI) of measured AAA between systolic CTA vs. systolic and diastolic MRA, 0.891 (CI 0.830-0.932) and 0.833 (CI 0.742-0.893), respectively; ICC with 95% CI of measured AVP between systolic CTA vs. systolic and diastolic MRA, 0.892 (CI 0.831-0.932) and 0.841 (CI 0.754-0.899). Of the 68 patients, 52 assigned the same device size, 2 assigned an oversized device, and 14 assigned undersized devices when sizing was based on systolic MRA as compared to systolic CTA. Virtual MRA-sizing assigned under-sizing for 14 patients, 9 of whom presented PAR grade 1 by CTA-sizing. This under-sizing could potentially increase the severity of PAR postoperatively, with the possibility of escalating PAR to grade 2 or above.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты