Revista espanola de cardiologia (English ed.) · 2024

Aortic valve calcification volume and prognosis in patients undergoing transcatheter aortic valve implantation.

СтатьяНаблюдательное исследованиеМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Álvarez-Covarrubias Héctor A, Altaner Niklas, Adolf Rafael, Jurisic Martin, Horban Elisabeth, Pellegrini Costanza, Duesmann Charlotte, Lachmann Mark, Thilo Christian, Syryca Finn, Klos Markus, Mayr N Patrick, Rheude Tobias, Renker Matthias, Charitos Efstratios I, Schunkert Heribert, Kastrati Adnan, Xhepa Erion, Won-Keun Kim, Joner Michael

Аннотация

INTRODUCTION AND OBJECTIVES: It is unknown whether aortic valve calcium volume, as measured by contrast-enhanced computed tomography angiography (angio-CT), is associated with mortality in patients undergoing transcatheter aortic valve implantation (TAVI). We aimed to confirm that contrast-enhanced aortic valve calcium correlates with noncontrast-enhanced calcium score and provides useful prognostic information in patients undergoing TAVI.

METHODS: This retrospective observational study included patients from 2 high-volume TAVI centers in Germany, all of whom underwent high-quality angio-CT prior to TAVI. Calcium volume in contrast-enhanced angio-CT was calculated using 3Mensio software (Pie Medical, The Netherlands), while the calcium score from noncontrast-enhanced angio-CT was obtained using the Syngo.via (Siemens Healthineers, Germany) workstation to validate contrast-enhanced angio-CT values. Calcium volume was dichotomized using the median based on to sex-specific values from contrast-enhanced angio-CT, and the risk associated with increased calcium volume was determined using Cox proportional hazard regression analysis.

RESULTS: We included 3318 TAVI patients. A good correlation was observed between noncontrast-enhanced and contrast-enhanced angio-CT (r2=0.680; P<.001). The median values for sex-specific contrast-enhanced angio-CT calcium volume were 514 mm3 for women and 1025 mm3 for men. Patients with higher calcium volumes showed lower mortality at 1 year (8.8% vs 12.1%; adjusted HR, 0.86; 95%CI, 0.75-0.98; P=.02) compared with those with lower calcium volumes.

CONCLUSIONS: Calcium volume in contrast-enhanced angio-CT correlated well with noncontrast-enhanced angio-CT calcium score. Patients with higher calcium volume showed lower mortality at 1 year after TAVI.