m+Medelevator.RU
← Поиск публикаций
The American journal of cardiology · 2024

Initial Findings Concerning the Latest Self-Expandable Evolut FX Valve: A Report Using OCEAN-TAVI Registry Data.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yashima Fumiaki, Yamamoto Masanori, Shirai Shinichi, Tada Norio, Naganuma Toru, Yamawaki Masahiro, Yamanaka Futoshi, Mizutani Kazuki, Noguchi Masahiko, Ueno Hiroshi, Takagi Kensuke, Ohno Yohei, Izumo Masaki, Nishina Hidetaka, Suzuyama Hiroto, Yamasaki Kazumasa, Nishioka Kenji, Hachinohe Daisuke, Fuku Yasushi, Otsuka Toshiaki, Asami Masahiko, Watanabe Yusuke, Hayashida Kentaro, OCEAN-TAVI investigators

Аннотация

Data concerning the clinical effect of the latest-generation self-expandable transcatheter heart valve (Evolut FX) remain limited. We aimed to assess the in-hospital outcomes of 3 bioprosthetic valves (Evolut EPO, PRO+, and FX). We analyzed data from a Japanese multicenter registry involving 634 consecutive patients who underwent transcatheter aortic valve replacement with Evolut FX up until October 2023. Patients who underwent transcatheter aortic valve replacement with Evolut EPO between 2018 and 2020 (n = 1,128), and those with Evolut EPO+ between 2020 and 2023 (n = 1,696) served as the control groups. The exclusion criteria comprised patients on dialysis with a history of infective endocarditis or with insufficient data. Unmatched comparisons among the 3 valves were conducted, followed by a propensity score-matched comparison between Evolut EPO+ and FX. In the unmatched cohort, among the Evolut EPO, PRO+, and FX groups, all vascular complications (7.8% vs 5.2% vs 4.5%, respectively, p <0.01) and new pacemaker implantation rates (11.2% vs 6.1% vs 7.7%, respectively, p <0.01) differed significantly. In the propensity score-matched analysis, the rate of all bleeding events was significantly higher in the Evolut EPO+ group (11.0%) than in the FX group (7.0%) (p = 0.02), whereas all vascular complications (4.6% vs 4.6%, respectively, p = 1.00) and new pacemaker implantation (5.9% vs 7.6%, respectively, p = 0.28) rates were comparable. The incidence of stroke in the FX group was approximately half that of the EP+ group (3.7% vs 1.9%, p = 0.095), without statistical significance. In conclusion, compared with the Evolut EPO+, Evolut FX was associated with a lower incidence of in-hospital bleeding complications and may reduce the incidence of in-hospital stroke.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты