MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.31195

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2024

First-in-human: Leaflet laceration with balloon mediated annihilation to prevent coronary obstruction with radiofrequency needle (LLAMACORN) for valve-in-valve transcatheter aortic valve replacement.

Mew Christina, Dahiya Arun, Chong Adrian A, Hayman Samual M, Moore Peter T, Harrop Danielle L, Reyaldeen Reza, Cole Christopher M W, Ross Jordan D W, Roberts Shaun, Korver Kellee A, Cox Stephen V, Camuglia Anthony C

Клинический случайVideo-Audio MediaСтатьяПеревод пока не подготовлен

Аннотация

Coronary obstruction (CO) is a potential pitfall for transcatheter aortic valve replacement (TAVR), especially in valve in valve procedures into degenerated surgical or transcatheter prostheses. Bioprosthetic leaflet modification techniques that incorporate electrosurgery are evolving as the preferred strategy to mitigate the risk of CO in high CO risk settings. The UNICORN method is proposed as a more predictable leaflet modification strategy than the earlier described BASILICA approach, but its proponents have hitherto mandated the use of a balloon-expandable valve (BEV) prosthesis. Many patients have small prostheses and therein face a significant risk of patient prosthesis mismatch with BEV in this setting. This risk may be curtailed if a self-expanding valve (SEV) prosthesis could be used. Herein described is a modified approach to allow for the utilization of SEV systems in this setting.

Для цитирования: Mew Christina, Dahiya Arun, Chong Adrian A, Hayman Samual M, Moore Peter T, Harrop Danielle L, Reyaldeen Reza, Cole Christopher M W, Ross Jordan D W, Roberts Shaun, Korver Kellee A, Cox Stephen V, Camuglia Anthony C. First-in-human: Leaflet laceration with balloon mediated annihilation to prevent coronary obstruction with radiofrequency needle (LLAMACORN) for valve-in-valve transcatheter aortic valve replacement.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2024. DOI: 10.1002/ccd.31195.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.