Aortic balloon valvuloplasty outcome according to calcium distribution and valve geometry - The ABCD study.

Dall'Ara Gianni, Piciucchi Sara, Moretti Carolina, Cavazza Caterina, Compagnone Miriam, Guerrieri Giuseppe, Grotti Simone, Spartà Daniela, Carletti Roberto, Fabbri Elisabetta, Giampalma Emanuela, Santarelli Andrea, Ottani Filippo, Balducelli Marco, Saia Francesco, Tarantino Fabio Felice, Galvani Marcello

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

There is little data on the outcome of balloon aortic valvuloplasty (BAV) in relation to valve dimensions and calcification patterns. The procedure is not standardized, particularly the choice of balloon size.

METHODS

This retrospective multicenter study focused on BAV efficacy and safety by analyzing the relationship between balloon size, annulus geometry (i.e., diameters, perimeter, and area), and calcification patterns (total burden and calcium distribution over each individual leaflet). From March 2018 to March 2023, all consecutive patients who underwent clinically indicated BAV and ECG-gated multidetector computed tomography of the aorta were included, except those with a bicuspid valve. Calcium score was calculated on contrast-enhanced images based on a luminal attenuation threshold of +100 HU.

RESULTS

One hundred and fifteen patients were included. Procedural success was 82.6 %. The balloon-to-annulus ratio (BAR) relative to diameter, perimeter, and area was higher in patients with successful BAV. Patients with unsuccessful BAV had a significantly higher aortic valve calcium burden. The complication rate was 4.3 % and there was no association with valve geometry or calcium burden. A trend towards a reduced complication rate was found as calcium asymmetry increased. BAR minimum annulus diameter was the best parameter in predicting procedural success, with a cut-off at 0.85.

CONCLUSIONS

BAV efficacy is correlated directly with balloon size in relation to annulus dimension and inversely with total calcium burden. The minimum diameter of the valve may be adopted as a reference for balloon sizing.

Для цитирования: Dall'Ara Gianni, Piciucchi Sara, Moretti Carolina, Cavazza Caterina, Compagnone Miriam, Guerrieri Giuseppe, Grotti Simone, Spartà Daniela, Carletti Roberto, Fabbri Elisabetta, Giampalma Emanuela, Santarelli Andrea, Ottani Filippo, Balducelli Marco, Saia Francesco, Tarantino Fabio Felice, Galvani Marcello. Aortic balloon valvuloplasty outcome according to calcium distribution and valve geometry - The ABCD study.. Cardiovascular revascularization medicine : including molecular interventions. 2024. DOI: 10.1016/j.carrev.2024.08.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.