Alekseev I M, Pekov Zh Zh, Pedyash N V, Zuev A A
Аннотация
UNLABELLED: Robot-assisted implantation of deep electrodes for stereo-EEG monitoring has become popular in recent years in patients with drug-resistant epilepsy. However, there are still few data on safety of this technique.
OBJECTIVE: To assess the incidence of complications in patients with drug-resistant epilepsy undergoing robot-assisted implantation of stereo-EEG electrodes.
MATERIAL AND METHODS: We retrospectively studied the results of implantation of stereo-EEG electrodes in 187 patients with drug-resistant epilepsy. All patients underwent non-invasive preoperative examination (video-EEG, MRI, PET, SPECT, MEG). In case of insufficient data, stereo-EEG monitoring was prescribed. We determined electrode insertion trajectory using a robotic station and MR images. Implantation of electrodes was carried out using a Rosa robot (Medtech, France). All patients underwent invasive EEG monitoring after implantation.
RESULTS: There were 11.25±3 electrodes per a patient. Implantation of one electrode took 7.5±4.9 min. Postoperative MRI revealed electrode malposition in 2.3% of cases. None was associated with complications. The complication rate per electrode was 0.6%. Complications affected stereo-EEG monitoring only in 3 cases (1.6%). The mortality rate was 0.5%. Bilateral implantation (p=0.005), insular (p=0.040) and occipital (p=0.045) deep electrode implantation were associated with lower incidence of complications. Longer duration of the procedure influenced the incidence of electrode placement in the lateral ventricle (p=0.028), and implantation in the frontal lobe was more often associated with epidural placement of electrodes (p=0.039).
CONCLUSION: Robot-assisted implantation of stereo-EEG electrodes is a safe procedure with minimal risk of complications. Rare electrode malposition does not usually affect invasive monitoring.
OBJECTIVE: To assess the incidence of complications in patients with drug-resistant epilepsy undergoing robot-assisted implantation of stereo-EEG electrodes.
MATERIAL AND METHODS: We retrospectively studied the results of implantation of stereo-EEG electrodes in 187 patients with drug-resistant epilepsy. All patients underwent non-invasive preoperative examination (video-EEG, MRI, PET, SPECT, MEG). In case of insufficient data, stereo-EEG monitoring was prescribed. We determined electrode insertion trajectory using a robotic station and MR images. Implantation of electrodes was carried out using a Rosa robot (Medtech, France). All patients underwent invasive EEG monitoring after implantation.
RESULTS: There were 11.25±3 electrodes per a patient. Implantation of one electrode took 7.5±4.9 min. Postoperative MRI revealed electrode malposition in 2.3% of cases. None was associated with complications. The complication rate per electrode was 0.6%. Complications affected stereo-EEG monitoring only in 3 cases (1.6%). The mortality rate was 0.5%. Bilateral implantation (p=0.005), insular (p=0.040) and occipital (p=0.045) deep electrode implantation were associated with lower incidence of complications. Longer duration of the procedure influenced the incidence of electrode placement in the lateral ventricle (p=0.028), and implantation in the frontal lobe was more often associated with epidural placement of electrodes (p=0.039).
CONCLUSION: Robot-assisted implantation of stereo-EEG electrodes is a safe procedure with minimal risk of complications. Rare electrode malposition does not usually affect invasive monitoring.