Journal of diabetes and its complications · 2024
Delayed prandial insulin boluses are an important determinant of blood glucose control and relate to fear of hypoglycemia in people with type 1 diabetes on advanced technologies.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Annuzzi Giovanni, Triggiani Raffaella, De Angelis Raffaele, Rainone Carmen, Corrado Alessandra, Scidà Giuseppe, Lupoli Roberta, Bozzetto Lutgarda
Аннотация
AIMS: Automated insulin delivery systems improve blood glucose control in patients with type 1 diabetes (T1D). However, optimizing their performance requires patient's proper compliance to meal insulin bolus administration. We explored real-life prevalence of delayed prandial boluses (DBs) in adults with T1D on advanced technologies, and their association with glycemic control and fear of hypoglycemia (FH).
METHODS: In the last two-week web-based reports of 152 adults with T1D on Hybrid Closed Loop Systems (HCLS) or Sensor Augmented Pump (SAP), DBs were identified when a steep increase in blood glucose occurred at CGM before the prandial bolus, and CGM metrics were evaluated. All participants completed an online questionnaire on FH.
RESULTS: Mean DBs over two weeks were 10.2 ± 4.7 (M ± SD, range 1-23) and more frequent in women than men (11.0 ± 4.6 vs. 9.4 ± 4.7, p = 0.036). Participants with more DBs (>12) showed significantly lower Time-In-Range (62.4 ± 13.8 vs. 76.6 ± 9.0 %) than those with less DBs (<7.7), along with higher Time-Above-Range, GMI, and Coefficient-of-Variation (ANOVA, p < 0.001 for all). Participants with higher FH score showed more DBs (11.6 ± 5.0) than those in lower tertiles (9.57 ± 4.59 and 9.47 ± 4.45, ANOVA p = 0.045).
CONCLUSIONS: In patients on advanced technologies, delayed boluses are extremely common, and associate with significantly worse glycemic control. Utmost attention is needed to bolus timing, mainly tackling fear of hypoglycemia.
METHODS: In the last two-week web-based reports of 152 adults with T1D on Hybrid Closed Loop Systems (HCLS) or Sensor Augmented Pump (SAP), DBs were identified when a steep increase in blood glucose occurred at CGM before the prandial bolus, and CGM metrics were evaluated. All participants completed an online questionnaire on FH.
RESULTS: Mean DBs over two weeks were 10.2 ± 4.7 (M ± SD, range 1-23) and more frequent in women than men (11.0 ± 4.6 vs. 9.4 ± 4.7, p = 0.036). Participants with more DBs (>12) showed significantly lower Time-In-Range (62.4 ± 13.8 vs. 76.6 ± 9.0 %) than those with less DBs (<7.7), along with higher Time-Above-Range, GMI, and Coefficient-of-Variation (ANOVA, p < 0.001 for all). Participants with higher FH score showed more DBs (11.6 ± 5.0) than those in lower tertiles (9.57 ± 4.59 and 9.47 ± 4.45, ANOVA p = 0.045).
CONCLUSIONS: In patients on advanced technologies, delayed boluses are extremely common, and associate with significantly worse glycemic control. Utmost attention is needed to bolus timing, mainly tackling fear of hypoglycemia.