The American journal of cardiology · 2024
Outcomes of Valve-in-Valve Transcatheter Aortic Valve Replacement.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Ahmad Danial, Yousef Sarah, Kliner Dustin, Brown James A, Serna-Gallegos Derek, Toma Catalin, Makani Amber, West David, Wang Yisi, Thoma Floyd W, Sultan Ibrahim
Аннотация
Structural valve degeneration is increasingly seen given the higher rates of bioprosthetic heart valve use for surgical and transcatheter aortic valve replacement (TAVR). Valve-in-valve TAVR (VIV-TAVR) is an attractive alternate for patients who are otherwise at high risk for reoperative surgery. We compared patients who underwent VIV-TAVR and native valve TAVR through a retrospective analysis of our institutional transcatheter valve therapy (TVT) database from 2013 to 2022. Patients who underwent either a native valve TAVR or VIV-TAVR were included. VIV-TAVR was defined as TAVR in patients who underwent a previous surgical aortic valve replacement. Kaplan-Meier survival analysis was used to obtain survival estimates. A Cox proportional hazards regression model was used for the multivariable analysis of mortality. A total of 3,532 patients underwent TAVR, of whom 198 (5.6%) underwent VIV-TAVR. Patients in the VIV-TAVR cohort were younger than patients who underwent native valve TAVR (79.5 vs 84 years, p <0.001), with comparable number of women and a higher Society of Thoracic Surgeons risk score (6.28 vs 4.46, p <0.001). The VIV-TAVR cohort had a higher incidence of major vascular complications (2.5% vs 0.8%, p = 0.008) but lower incidence of permanent pacemaker placement (2.5% vs 8.1%, p = 0.004). The incidence of stroke was comparable between the groups (VIV-TAVR 2.5% vs native TAVR 2.4%, p = 0.911). The 30-day readmission rates (VIV-TAVR 7.1% vs native TAVR 9%, p = 0.348), as well as in-hospital (VIV-TAVR 2% vs native TAVR 1.4%, p = 0.46), and overall (VIV-TAVR 26.3% vs native TAVR 30.8%, p = 0.18) mortality at a follow-up of 1.8 years (0.83 to 3.5) were comparable between the groups. The survival estimates were also comparable between the groups (log-rank p = 0.27). On multivariable Cox regression analysis, VIV-TAVR was associated with decreased hazards of death (hazard ratio 0.68 [0.5 to 0.9], p = 0.02). In conclusion, VIV-TAVR is a feasible and safe strategy for high-risk patients with bioprosthetic valve failure. There may be potentially higher short-term morbidity with VIV-TAVR, with no overt impact on survival.