Аннотация

INTRODUCTION: In recent years, intracardiac electrocardiogram (IC-ECG) technology has been widely used for epicutaneo-cava catheter (ECC) placement and has shown many potential advantages. However, evidence about the quantitative changes, effectiveness, and safety of IC-ECG for lower extremity ECC is sparse. This study aimed to explore the quantitative changes in IC-ECG for lower extremity ECC and determine its effectiveness and safety.

METHODS: A retrospective study was conducted on 303 premature infants who underwent successful IC-ECG-guided lower extremity ECC placement between January 2019 and December 2021. All patients underwent chest X-ray postoperatively to verify the position of the catheter tip. The amplitudes of the surface electrocardiogram and IC-ECG QRS waves and the difference between the two amplitudes were measured. The effectiveness (matching rate between IC-ECG and chest X-ray) and safety (incidence of catheter-related complications) of IC-ECG for lower extremity ECC were evaluated.

RESULTS: The matching rate between IC-ECG and chest X-ray was 95.0%. When the catheter tip was optimally positioned, the QRS amplitude of the IC-ECG was 0.85 ± 0.56 mv higher than that of the surface electrocardiogram. The overall incidence of catheter-related complications was 10.6%. The actual ECC insertion length was associated with a noticeably increased risk of catheter-related complications.

CONCLUSIONS: This study suggests that IC-ECG is an effective and safe method by observing the dynamic changes in both QRS complexes and P wave to locate the tip of lower extremity ECC in preterm infants. Our findings would facilitate the application of IC-ECG for ECC localization.