DOI 10.1016/j.hrthm.2023.09.017

Медицинская библиотека · Heart rhythm · 2023

Outcomes of patients implanted with an atrioventricular synchronous leadless ventricular pacemaker in the Medicare population.

Crossley George H, Longacre Colleen, Higuera Lucas, Stromberg Kurt, Cheng Alan, Piccini Jonathan P, El-Chami Mikhael F

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The Micra AV Coverage with Evidence Development study is a novel analysis of utilization and outcomes associated with Micra AV leadless pacing in US Medicare patients.

OBJECTIVE

The purpose of this study was to describe patient characteristics, complications, and outcomes of patients implanted with a Micra AV leadless pacemaker compared with a contemporaneous cohort of patients implanted with a dual chamber transvenous pacemaker.

METHODS

Patients implanted with Micra AV (n = 7471) or a dual chamber transvenous pacemaker (n = 107,800) from February 5, 2020, through December 1, 2021, were identified using device registry-linked Medicare claims data. Acute complications were assessed at 30 days, and chronic complications, reinterventions, and all-cause mortality were assessed at 6 months.

RESULTS

Patients implanted with Micra AV had higher rates of end-stage renal disease (14.9% vs 2.0%; P < .0001) and overall comorbidity burden (mean Charlson Comorbidity Index 4.9 vs 3.8; P < .0001). There was no difference in the unadjusted rate of complications at 30 days (9.1% vs 8.7%; P = .61), and patients implanted with Micra AV had a significantly lower adjusted rate of complications (8.6% vs 11.0%; P < .0001). At 6 months, patients implanted with Micra AV had significantly lower rates of complications (adjusted hazard ratio 0.50; 95% confidence interval 0.43-0.57; P < .0001) and reinterventions (adjusted hazard ratio 0.46; 95% confidence interval 0.36-0.58; P < .0001). Patients implanted with Micra AV had higher all-cause mortality at 30 days and 6 months, likely because of differences in the underlying risk of mortality.

CONCLUSION

Patients implanted with Micra AV had similar rates of complications at 30 days and significantly lower rates of complications and reinterventions at 6 months, despite being sicker than patients implanted with a transvenous pacemaker.

Для цитирования: Crossley George H, Longacre Colleen, Higuera Lucas, Stromberg Kurt, Cheng Alan, Piccini Jonathan P, El-Chami Mikhael F. Outcomes of patients implanted with an atrioventricular synchronous leadless ventricular pacemaker in the Medicare population.. Heart rhythm. 2023. DOI: 10.1016/j.hrthm.2023.09.017.