Медицинская библиотека · Heart (British Cardiac Society) · 2023

Predictors and outcomes of pacemaker implantation in patients with cardiac amyloidosis.

Saturi Giulia, De Frutos Fernando, Sguazzotti Maurizio, Gonzalez-Lopez Esther, Nardi Elena, Domínguez Fernando, Ponziani Alberto, Cabrera Eva, Caponetti Angelo Giuseppe, Lozano Sara, Massa Paolo, Cobo-Marcos Marta, Accietto Antonella, Castro-Urda Victor, Giovannetti Alessandro, Toquero Jorge, Gagliardi Christian, Gómez-Bueno Manuel, Rios-Tamayo Rafael, Biagini Elena, Segovia Javier, Galiè Nazzareno, García-Pavía Pablo, Longhi Simone

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

We sought to investigate prevalence, incidence and prognostic implications of permanent pacemaker (PPM) implantation in patients with cardiac amyloidosis (CA), thereby identifying the predictors of time to PPM implantation.

METHODS

Seven hundred eighty-seven patients with CA (602 men, median age 74 years, 571 transthyretin amyloidosis (ATTR), 216 light-chain amyloidosis (AL)) evaluated at two European referral centres were retrospectively included. Clinical, laboratory and instrumental data were analysed. The associations between PPM implantation and mortality, heart failure (HF) or a composite endpoint of mortality, cardiac transplantation and HF were analysed.

RESULTS

81 (10.3%) patients had a PPM before initial evaluation. Over a median follow-up time of 21.7 months (IQR 9.6-45.2), 81 (10.3%) additional patients (18 with AL (22.2%) and 63 with ATTR (77.8%)) underwent PPM implantation with a median time to implantation of 15.6 months (IQR 4.2-40), complete atrioventricular block was the most common indication (49.4%). Independent predictors of PPM implantation were QRS duration (HR 1.03, 95% CI 1.02 to 1.03, p<0.001) and interventricular septum (IVS) thickness (HR 1.1, 95% CI 1.03 to 1.17, p=0.003). The model to estimate the probability of PPM at 12 months and containing both factors showed a C-statistic of 0.71 and a calibration of slope of 0.98.

CONCLUSIONS

Conduction system disease requiring PPM is a common complication in CA that affects up to 20.6% of patients. QRS duration and IVS thickness are independently associated with PPM implantation. A PPM implantation at 12 months model was devised and validated to identify patients with CA at higher risk of requiring a PPM and who require closer follow-up.

Для цитирования: Saturi Giulia, De Frutos Fernando, Sguazzotti Maurizio, Gonzalez-Lopez Esther, Nardi Elena, Domínguez Fernando, Ponziani Alberto, Cabrera Eva, Caponetti Angelo Giuseppe, Lozano Sara, Massa Paolo, Cobo-Marcos Marta, Accietto Antonella, Castro-Urda Victor, Giovannetti Alessandro, Toquero Jorge, Gagliardi Christian, Gómez-Bueno Manuel, Rios-Tamayo Rafael, Biagini Elena, Segovia Javier, Galiè Nazzareno, García-Pavía Pablo, Longhi Simone. Predictors and outcomes of pacemaker implantation in patients with cardiac amyloidosis.. Heart (British Cardiac Society). 2023. DOI: 10.1136/heartjnl-2022-322315.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.