Journal of the American College of Cardiology · 2025
ACC/AHA/ASE/HFSA/HRS/SCAI/SCCT/SCMR 2025 Appropriate Use Criteria for Implantable Cardioverter-Defibrillators, Cardiac Resynchronization Therapy, and Pacing.
СтатьяКлинические рекомендацииНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Russo Andrea M, Desai Milind Y, Do Monika M, Butler Javed, Chung Mina K, Epstein Andrew E, Guglin Maya E, Levy Wayne C, Piccini Jonathan P, Bhave Nicole M, Russo Andrea M, Desai Milind Y, Do Monika M, Ambardekar Amrut V, Berg Nancy C, Bilchick Kenneth C, Dec G William, Gopinathannair Rakesh, Han Janet K, Klein Liviu, Lampert Rachel J, Panjrath Gurusher S, Reeves Ryan R, Yoerger Sanborn Danita Marie, Stevenson Lynne W, Truong Quynh A, Varosy Paul D, Villines Todd C, Volgman Annabelle S, Zareba Karolina M
Аннотация
This appropriate use criteria (AUC) document is developed by the American College of Cardiology along with key specialty and subspecialty societies. It provides a comprehensive review of common clinical scenarios where implantable cardioverter-defibrillator (ICD), cardiac resynchronization therapy (CRT), cardiac contractility modulation, leadless pacing, and conduction system pacing therapies are frequently considered. The 335 clinical scenarios covered in this document address ICD indications including those related to secondary prevention, primary prevention, comorbidities, generator replacement at elective replacement indicator, dual-chamber, and totally subcutaneous ICDs, as well as device indications related to CRT, conduction system pacing, leadless pacing, cardiac contractility modulation, and ICD therapy in the setting of left ventricular assist devices (LVADs). The indications (clinical scenarios) were derived from common applications or anticipated uses, as well as from current clinical practice guidelines and results of studies examining device implantation. The indications in this document were developed by a multidisciplinary writing group and scored by a separate independent rating panel on a scale of 1 to 9 to designate care that is considered “Appropriate” (median 7 to 9), “May Be Appropriate” (median 4 to 6), and “Rarely Appropriate” (median 1 to 3). The final ratings reflect the median score of the 17 rating panel members. In general, Appropriate designations were assigned to scenarios for which clinical trial evidence and/or clinical experience was available that supported device implantation. In contrast, scenarios for which clinical trial evidence was limited or device implantation seemed reasonable for extenuating or practical reasons were categorized as May Be Appropriate. Scenarios for which there were data showing harm, or no data were available, and medical judgment deemed device therapy was illadvised were categorized as Rarely Appropriate. For example, comorbidities including reduced life expectancy related to noncardiac conditions or severe cognitive dysfunction would negatively impact appropriateness ratings. The appropriate use criteria for ICD, CRT, and pacing have the potential to enhance clinician decision making, healthcare delivery, and payment policy. Furthermore, recognition of clinical scenarios rated as May Be Appropriate facilitates the identification of areas where there may be gaps in evidence that would benefit from future research.