OBJECTIVE

To describe the long-term results, quality of life and chronic pain after chest wall fixation for traumatic rib fracture using a quality of life (QOL) score and a numeric pain score.

METHODS

Retrospective analysis of 10 consecutive patients who underwent surgery for rib fractures after trauma and reconstruction between October 2010 and March 2012. Chest rib fractures were fixed with titanium clips and bars or titanium plates and screws through a posterolateral thoracotomy. Pain was assessed with a numeric pain scale 0-10 and quality of life (QOL) with the EORTC questionnaire QLQ-C30.

RESULTS

There were 5 males and 5 females. The median age was 58 years (range 21-80). There were no postoperative deaths. The only postoperative complication observed was a contralateral pleural effusion requiring drainage. Median length of stay of the drain and median length of hospital stay were 2 days (range 0-8) and 4 days (range 1-42 days), respectively. The average follow-up period of operatively managed patients was 14 months (range 8-23.5 months). Seven patients scored the pain as 0, one as 1 (mild), one as 4 (moderate) and one as 8 (severe). Only two patients are taking occasionally pain killers. Only one patient presents severe limitation in his life scoring his QOL as poor.

CONCLUSIONS

Titanium devices (clips and bars; screws and plates) are effective and safe for repair of rib fractures and showed good long-term results in terms of pain and quality of life after the operation.

Для цитирования: Billè Andrea, Okiror Lawrence, Campbell Aideen, Simons Jason, Routledge Tom. Evaluation of long-term results and quality of life in patients who underwent rib fixation with titanium devices after trauma.. General thoracic and cardiovascular surgery. 2013. DOI: 10.1007/s11748-013-0218-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.