Long-Term Outcomes After Transcatheter Aortic Valve-in-Valve Replacement.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

de Freitas Campos Guimarães Leonardo, Urena Marina, Wijeysundera Harindra C, Munoz-Garcia Antonio, Serra Vicenç, Benitez Luis M, Auffret Vincent, Cheema Asim N, Amat-Santos Ignacio J, Fisher Quentin, Himbert Dominique, Garcia Del Blanco Bruno, Dager Antonio, Le Breton Hervé, Paradis Jean-Michel, Dumont Eric, Pibarot Philippe, Rodés-Cabau Josep

Аннотация

BACKGROUND: Data on long-term outcomes after valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) are scarce. The objective of this study was to determine the long-term clinical outcomes and structural valve degeneration (SVD) over time in patients undergoing ViV-TAVR.

METHODS AND RESULTS: Consecutive patients undergoing ViV-TAVR in 9 centers between 2009 and 2015 were included. Patients were followed yearly, and clinical and echocardiography data were collected prospectively. SVD was defined as subclinical (increase >10 mm Hg in mean transvalvular gradient+decrease >0.3 cm2 in valve area or new-onset mild or moderate aortic regurgitation) and clinically relevant (increase >20 mm Hg in mean transvalvular gradient+decrease >0.6 cm2 in valve area or new-onset moderate-to-severe aortic regurgitation). A total of 116 patients (mean age, 76±11 years; 64.7% male; mean Society of Thoracic Surgeons score, 8.0±5.1%) were included. Balloon- and self-expandable valves were used in 47.9% and 52.1% of patients, respectively, and 30-day mortality was 6.9%. At a median follow-up of 3 years (range, 2-7 years), 30 patients (25.9%) had died, 20 of them (17.2%) from cardiovascular causes. Average mean transvalvular gradients remained stable up to 5-year follow-up ( P=0.92), but clinically relevant SVD occurred in 3/99 patients (3.0%), and 15/99 patients (15.1%) had subclinical SVD. One patient with SVD had redo ViV-TAVR.

CONCLUSIONS: About one-fourth of ViV-TAVR recipients had died after a median follow-up of 3 years. Overall valve hemodynamics remained stable over time and clinically relevant SVD was infrequent, but 1 out of 10 patients exhibited some degree of SVD.