Functional Outcomes of Type I Bicuspid Aortic Valve Repair With Annular Stabilization: Subcommissural Annuloplasty Versus External Subannular Aortic Ring.

Ko Hanjo, Bavaria Joseph E, Habertheuer Andreas, Augoustides John G, Siki Mary A, Freas Melanie, Komlo Caroline, Milewski Karianna, Desai Nimesh D, Szeto Wilson Y, Vallabhajosyula Prashanth

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

In bicuspid aortic valve patients with nonaneurysmal root (<45 mm) and severe aortic insufficiency (AI), external subannular aortic ring (ESAR) is being increasingly utilized for annular stabilization, compared with traditional subcommissural annuloplasty (SCA). To this date, there is no comparative study assessing functional equivalence or superiority of ESAR over SCA.

METHODS

From 2003 to 2017, 139 patients underwent type I bicuspid aortic valve repair, of which 50 patients underwent concomitant SCA and 24 underwent ESAR. Cases with suboptimal echocardiographic imaging were excluded, resulting in 38 patients in the SCA group and 20 patients in ESAR group. Intraoperative transesophageal echocardiography before and after procedure were retrospectively analyzed for 11 parameters in the functional aortic root complex.

RESULTS

ESAR patients had larger preoperative annulus (28.3 ± 3.2 mm versus 29.8 ± 3.7 mm, p = 0.1) and left ventricular (LV) outflow tract (28.1 ± 3.5 mm versus 29.8 ± 4.0 mm, p = 0.1) diameters, with greater leaflet prolapse (3.4 ± 1.3 mm versus 4.3 ± 1.3, p = 0.02). In both groups, 100% freedom from AI greater than 1+ was achieved, with significant reduction of vena contracta (-3.0 ± 0.6 mm, p < 0.001; -3.2 ± 0.4 mm, p < 0.001) and level of eccentricity of AI jet (AI angle change: -24.3 ± 6.5 degrees, p = 0.002; -22.3 ± 7.2 degrees, p = 0.01). Reduction in LV dimensions (-7.1 ± 1.2 mm, p < 0.001; -8.9 ± 1.9 mm, p < 0.001), annulus (-3.4 ± 0.4 mm, p < 0.001; -5.1 ± 2.7 mm, p < 0.001), LV outflow tract (-2.3 ± 0.4 mm, p < 0.001; -4.4 ± 0.5 mm, p < 0.001), and degree of leaflet prolapse (-1.6 ± 0.4 mm, p = 0.005; -2.1 ± 0.4 mm, p = 0.001) was achieved in both groups. Comparison of postprocedure outcomes showed improved mean transvalvular gradients in ESAR (11.2 ± 5.7 mm Hg versus 7.1 ± 2.5 mm Hg, p = 0.003), with similar freedom from AI.

CONCLUSIONS

In addition to providing equivalent and excellent freedom from AI, ESAR also renders a more robust annular reduction than SCA, along with improved transvalvular gradients.

Для цитирования: Ko Hanjo, Bavaria Joseph E, Habertheuer Andreas, Augoustides John G, Siki Mary A, Freas Melanie, Komlo Caroline, Milewski Karianna, Desai Nimesh D, Szeto Wilson Y, Vallabhajosyula Prashanth. Functional Outcomes of Type I Bicuspid Aortic Valve Repair With Annular Stabilization: Subcommissural Annuloplasty Versus External Subannular Aortic Ring.. The Annals of thoracic surgery. 2018. DOI: 10.1016/j.athoracsur.2018.06.056.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.