MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2018.06.026

Медицинская библиотека · The Annals of thoracic surgery · 2018

Predictors of Recurrent Aortic Insufficiency in Type I Bicuspid Aortic Valve Repair.

Habertheuer Andreas, Milewski Rita Karianna, Bavaria Joseph E, Siki Mary, Freas Melanie, Desai Nimesh, Szeto Wilson, Ram Chirag, Hu Robert, Vallabhajosyula Prashanth

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Annular stabilization techniques in bicuspid aortic valve (BAV) repair include valve-sparing root reimplantation (VSRR), external subannular aortic ring (ESAR), and subcommissural annuloplasty (SCA). Unlike VSRR that offers neoroot creation, ESAR and SCA offer annular reduction only. We compared long-term functional outcomes to understand BAV repair durability.

METHODS

From 2004 to 2017, 137 patients underwent Sievers type I BAV repair (VSRR, n = 54; ESAR, n = 22; SCA, n = 51). Prospectively maintained BAV repair database was queried for clinical and functional outcomes. Data were analyzed by logistic regression, threshold regression, multistate survival, and transition models for BAV repair durability.

RESULTS

VSRR patients had larger preoperative sinus dimensions (p < 0.001), but mean preoperative annulus size was similar for VSRR, ESAR, and SCA (29.3 ± 3.7 mm, 29.8 ± 3.8 mm, and 29.7 ± 3.8mm, respectively; p = 0.807). Degree of annular reduction (p = 0.280) was comparable between the groups. Intraoperative postrepair freedom from aortic insufficiency (AI) 1+ or greater was 100% across the entire cohort. By logistic regression, important predictors of recurrent AI (1+ and ≥2+) were preoperative annulus of 30 mm or more for SCA. Threshold regression confirmed annulus of 30 mm or more as risk factor for recurrent AI of 1+ or greater for SCA. Risk to relapse from no AI to AI 1+ was equal between the groups; however, once AI 1+ was reached, there was a 2.5-fold increased risk for patients with annulus of 30 mm or more who underwent SCA to progress to recurrent AI of 2+ or greater.

CONCLUSIONS

VSRR is associated with improved longitudinal BAV durability compared with SCA. Preoperative annulus diameter of 30 mm or more is associated with increased recurrent AI, especially for SCA patients. For annular indications, ESAR might offer comparable functional outcomes with VSRR; however, further follow-up is critical.

Для цитирования: Habertheuer Andreas, Milewski Rita Karianna, Bavaria Joseph E, Siki Mary, Freas Melanie, Desai Nimesh, Szeto Wilson, Ram Chirag, Hu Robert, Vallabhajosyula Prashanth. Predictors of Recurrent Aortic Insufficiency in Type I Bicuspid Aortic Valve Repair.. The Annals of thoracic surgery. 2018. DOI: 10.1016/j.athoracsur.2018.06.026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.