m+Medelevator.RU
← Поиск публикаций
Circulation journal : official journal of the Japanese Circulation Society · 2018

Inter-Technique Consistency and Prognostic Value of Intra-Procedural Angiographic and Echocardiographic Assessment of Aortic Regurgitation After Transcatheter Aortic Valve Implantation.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tateishi Hiroki, Miyazaki Yosuke, Okamura Takayuki, Abdelghani Mohammad, Modolo Rodrigo, Wada Yasuaki, Okuda Shinichi, Omuro Ayumi, Ariyoshi Toru, Fujii Ayano, Oda Tetsuro, Fujimura Tatsuhiro, Nanno Takuma, Mikamo Akihito, Soliman Osama I I, Onuma Yoshinobu, Hamano Kimikazu, Yano Masafumi, Serruys Patrick W

Аннотация

BACKGROUND: We investigated the relationship between intraprocedural angiographic and echocardiographic AR severity after TAVI, and the clinical robustness of angiographic assessment.

METHODS AND RESULTS: In 74 consecutive patients, the echocardiographic circumferential extent (CE) of the paravalvular regurgitant jet was retrospectively measured and graded based on the VARC-2 cut-points; and angiographic post-TAVI AR was retrospectively quantified using contrast videodensitometry (VD) software that calculates the ratio of the contrast time-density integral in the LV outflow tract to that in the ascending aorta (LVOT-AR). Seventy-four echocardiograms immediately after TAVI were analyzable, while 51 aortograms were analyzable for VD. These 51 echocardiograms and VD were evaluated. Median LVOT-AR across the echocardiographic AR grades was as follows: none-trace, 0.07 (IQR, 0.05-0.11); mild, 0.12 (IQR, 0.09-0.15); and moderate, 0.17 (IQR, 0.15-0.22; P<0.05 for none-trace vs. mild, and mild vs. moderate). LVOT-AR strongly correlated with %CE (r=0.72, P<0.0001). At 1 year, the rate of the composite end-point of all-cause death or HF re-hospitalization was significantly higher in >mild AR patients compared with no-mild AR on intra-procedural echocardiography (41.5% vs. 12.4%, P=0.03) as well as in patients with LVOT-AR >0.17 compared with LVOT-AR ≤0.17 (59.5% vs. 16.6%, P=0.03).

CONCLUSIONS: VD (LVOT-AR) has good intra-procedural inter-technique consistency and clinical robustness. Greater than mild post-TAVI AR, but not mild post-TAVI AR, is associated with late mortality.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты