Rodríguez-Olivares Ramón, El Faquir Nahid, Rahhab Zouhair, van Gils Lennart, Ren Ben, Sakhi Rafi, Geleijnse Marcel L, van Domburg Ron, de Jaegere Peter P T, Zamorano Gómez Jose L, Van Mieghem Nicolas M
Аннотация
AIMS: We sought to evaluate the interaction of different aortic root phenotypes with self-expanding (SEV), balloon-expandable (BEV) and mechanically expanded (MEV) and the impact on significant aortic regurgitation.
METHODS AND RESULTS: We included 392 patients with a SEV (N = 205), BEV (N = 107) or MEV (N = 80). Aortic annulus eccentricity index and calcification were measured by multi-slice CT scan. Paravalvular aortic regurgitation was assessed by contrast aortography (primary analysis) and transthoracic echocardiography (secondary analysis). In mildly calcified roots paravalvular regurgitation incidence was similar for all transcatheter heart valves (SEV 8.4%; BEV 9.1%; MEV 2.0% p = 0.27). Conversely, in heavily calcified roots paravalvular regurgitation incidence was significantly higher with SEV (SEV 45.9%; BEV 0.0%; MEV 0.0% p < 0.001). When paravalvular regurgitation was assessed by TTE, the overall findings were similar although elliptic aortic roots were associated with more paravalvular regurgitation with SEV (20.5% vs. BEV 4.5% vs. MEV 3.2%; p = 0.009).
CONCLUSIONS: In heavily calcified aortic roots, significant paravalvular aortic regurgitation is more frequent with SEV than with BEV or MEV, but similar in mildly calcified ones. These findings may support patient-tailored transcatheter heart valve selection.
CLASSIFICATIONS: Aortic stenosis; multislice computed tomography; transcatheter aortic valve replacement; paravalvular aortic regurgitation.
CONDENSED ABSTRACT: We sought to evaluate the interaction of different aortic root phenotypes with self-expanding (SEV), balloon-expandable (BEV) and mechanically expanded (MEV) and the impact on significant aortic regurgitation. We included 392 patients with a SEV (N = 205), BEV (N = 107) or MEV (N = 80). Aortic annulus eccentricity index and calcification were measured by multi-slice CT scan. Paravalvular aortic regurgitation was assessed by contrast aortography and transthoracic echocardiography. We found that in heavily calcified aortic roots, significant paravalvular aortic regurgitation is more frequent with SEV than with BEV or MEV, but similar in mildly calcified ones.
METHODS AND RESULTS: We included 392 patients with a SEV (N = 205), BEV (N = 107) or MEV (N = 80). Aortic annulus eccentricity index and calcification were measured by multi-slice CT scan. Paravalvular aortic regurgitation was assessed by contrast aortography (primary analysis) and transthoracic echocardiography (secondary analysis). In mildly calcified roots paravalvular regurgitation incidence was similar for all transcatheter heart valves (SEV 8.4%; BEV 9.1%; MEV 2.0% p = 0.27). Conversely, in heavily calcified roots paravalvular regurgitation incidence was significantly higher with SEV (SEV 45.9%; BEV 0.0%; MEV 0.0% p < 0.001). When paravalvular regurgitation was assessed by TTE, the overall findings were similar although elliptic aortic roots were associated with more paravalvular regurgitation with SEV (20.5% vs. BEV 4.5% vs. MEV 3.2%; p = 0.009).
CONCLUSIONS: In heavily calcified aortic roots, significant paravalvular aortic regurgitation is more frequent with SEV than with BEV or MEV, but similar in mildly calcified ones. These findings may support patient-tailored transcatheter heart valve selection.
CLASSIFICATIONS: Aortic stenosis; multislice computed tomography; transcatheter aortic valve replacement; paravalvular aortic regurgitation.
CONDENSED ABSTRACT: We sought to evaluate the interaction of different aortic root phenotypes with self-expanding (SEV), balloon-expandable (BEV) and mechanically expanded (MEV) and the impact on significant aortic regurgitation. We included 392 patients with a SEV (N = 205), BEV (N = 107) or MEV (N = 80). Aortic annulus eccentricity index and calcification were measured by multi-slice CT scan. Paravalvular aortic regurgitation was assessed by contrast aortography and transthoracic echocardiography. We found that in heavily calcified aortic roots, significant paravalvular aortic regurgitation is more frequent with SEV than with BEV or MEV, but similar in mildly calcified ones.
Предметные рубрики MeSH
Aortic ValveAortic Valve InsufficiencyAortic Valve StenosisAortographyBalloon ValvuloplastyCalcinosisComputed Tomography AngiographyEchocardiographyHeart Valve ProsthesisHemodynamicsHumansMultidetector Computed TomographyProsthesis DesignRetrospective StudiesRisk FactorsSeverity of Illness IndexTranscatheter Aortic Valve ReplacementTreatment Outcome