MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1378/chest.07-1481

Медицинская библиотека · Chest · 2007

Ventilator settings and outcome of respiratory failure in chronic interstitial lung disease.

Fernández-Pérez Evans R, Yilmaz Murat, Jenad Hussam, Daniels Craig E, Ryu Jay H, Hubmayr Rolf D, Gajic Ognjen

Сравнительное исследованиеСтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

BACKGROUND

While patients with interstitial lung disease (ILD) may be particularly susceptible to ventilator-induced lung injury, ventilator strategies have not been studied in this group of patients.

PURPOSES: To describe the clinical course and outcome of patients with ILD and acute respiratory failure in relation to ventilatory parameters.

METHODS

We retrospectively identified a cohort of ventilated patients with ILD who had been admitted to five ICUs at a single institution. We analyzed demographic data, pulmonary function test results, severity of illness, and the parameters of continuous ventilation for the initial 24 h after admission to the ICU. Primary outcomes were survival to hospital discharge and 1-year survival.

MAIN

RESULTS

Of 94 patients with ILD, 44 (47%) survived to hospital discharge and 39 (41%) were alive at 1 year. Nonsurvivors were less likely to be postoperative, had higher severity of illness, and were ventilated at higher airway pressures and lower tidal volumes. Step changes in positive end-expiratory pressure (PEEP) of > 10 cm H(2)O were attempted in 20 patients and resulted in an increase in plateau pressure (median difference, + 16 cm H(2)O; interquartile range [IQR], 9 to 24 cm H(2)O) and a decrease in respiratory system compliance (median difference, - 0.28 mL/kg/cm H(2)O; IQR, - 0.43 to - 0.13 mL/kg/cm H(2)O). The Cox proportional hazards model revealed that high PEEP (hazard ratio, 4.72; 95% confidence interval [CI], 2.06 to 11.15), acute physiology and chronic health evaluation (APACHE) III score predicted mortality (hazard ratio 1.33; 95% CI, 1.18 to 1.50), age (hazard ratio, 1.03; 95% CI, 1 to 1.05), and low Pao(2)/fraction of inspired oxygen ratio (hazard ratio, 0.96; 95% CI, 0.92 to 0.99) to be independent determinants of survival.

CONCLUSION

Both severity of illness and high PEEP settings are associated with the decreased survival of patients with ILD who are receiving mechanical ventilation.

Для цитирования: Fernández-Pérez Evans R, Yilmaz Murat, Jenad Hussam, Daniels Craig E, Ryu Jay H, Hubmayr Rolf D, Gajic Ognjen. Ventilator settings and outcome of respiratory failure in chronic interstitial lung disease.. Chest. 2007. DOI: 10.1378/chest.07-1481.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.