MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/1475-925x-6-40

Медицинская библиотека · Biomedical engineering online · 2007

Continuous negative extrathoracic pressure combined with high-frequency oscillation improves oxygenation with less impact on blood pressure than high-frequency oscillation alone in a rabbit model of surfactant depletion.

Naito Sachie, Hiroma Takehiko, Nakamura Tomohiko

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Negative air pressure ventilation has been used to maintain adequate functional residual capacity in patients with chronic muscular disease and to decrease transpulmonary pressure and improve cardiac output during right heart surgery. High-frequency oscillation (HFO) exerts beneficial effects on gas exchange in neonates with acute respiratory failure. We examined whether continuous negative extrathoracic pressure (CNEP) combined with HFO would be effective for treating acute respiratory failure in an animal model.

METHODS

The effects of CNEP combined with HFO on pulmonary gas exchange and circulation were examined in a surfactant-depleted rabbit model. After induction of severe lung injury by repeated saline lung lavage, 18 adult white Japanese rabbits were randomly assigned to 3 groups: Group 1, CNEP (extra thoracic negative pressure, -10 cmH2O) with HFO (mean airway pressure (MAP), 10 cmH2O); Group 2, HFO (MAP, 10 cmH2O); and Group 3, HFO (MAP, 15 cmH2O). Physiological and blood gas data were compared among groups using analysis of variance.

RESULTS

Group 1 showed significantly higher oxygenation than Group 2, and the same oxygenation with significantly higher mean blood pressure compared to Group 3.

CONCLUSION

Adequate CNEP combined with HFO improves oxygenation with less impact on blood pressure than high-frequency oscillation alone in an animal model of respiratory failure.

Для цитирования: Naito Sachie, Hiroma Takehiko, Nakamura Tomohiko. Continuous negative extrathoracic pressure combined with high-frequency oscillation improves oxygenation with less impact on blood pressure than high-frequency oscillation alone in a rabbit model of surfactant depletion.. Biomedical engineering online. 2007. DOI: 10.1186/1475-925x-6-40.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.