MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mat.0b013e318031af3b

Медицинская библиотека · ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2007

Evaluation of fiber bundle rotation for enhancing gas exchange in a respiratory assist catheter.

Eash Heide J, Mihelc Kevin M, Frankowski Brian J, Hattler Brack G, Federspiel William J

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Supplemental oxygenation and carbon dioxide removal through an intravenous respiratory assist catheter can be used as a means of treating patients with acute respiratory failure. We are beginning development efforts toward a new respiratory assist catheter with an insertional size <25F, which can be inserted percutaneously. In this study, we evaluated fiber bundle rotation as an improved mechanism for active mixing and enhanced gas exchange in intravenous respiratory assist catheters. Using a simple test apparatus of a rotating densely packed bundle of hollow fiber membranes, water and blood gas exchange levels were evaluated at various rotation speeds in a mock vena cava. At 12,000 RPM, maximum CO2 gas exchange rates were 449 and 523 mL/min per m2, water and blood, respectively, but the rate of increase with increasing rotation rate diminished beyond 7500 RPM. These levels of gas exchange efficiency are two- to threefold greater than achieved in our previous respiratory catheters using balloon pulsation for active mixing. In preliminary hemolysis tests, which monitored plasma-free hemoglobin levels in vitro over a period of 6 hours, we established that the rotating fiber bundle per se did not cause significant blood hemolysis compared with an intra-aortic balloon pump. Accordingly, fiber bundle rotation appears to be a potential mechanism for increasing gas exchange and reducing insertional size in respiratory catheters.

Для цитирования: Eash Heide J, Mihelc Kevin M, Frankowski Brian J, Hattler Brack G, Federspiel William J. Evaluation of fiber bundle rotation for enhancing gas exchange in a respiratory assist catheter.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2007. DOI: 10.1097/mat.0b013e318031af3b.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.