DOI 10.1211/jpp.58.11.0017

Медицинская библиотека · The Journal of pharmacy and pharmacology · 2006

Enhanced delivery of nebulised salbutamol during non-invasive ventilation.

Calvert Lori D, Jackson Judith M, White Judy A, Barry Peter W, Kinnear William J, O'Callaghan Christopher

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

Non-invasive ventilation (NIV) is used to treat acute respiratory failure. Nebulised drugs can be delivered concurrently with NIV or during breaks from ventilatory support. We hypothesised that the amount of nebulised salbutamol inhaled when delivered via bi-level ventilation would be no different to the amount available directly from the same nebuliser. A standard bi-level ventilation circuit was attached to a lung model simulating adult respiration. Drug delivery was compared when salbutamol (5 mg) was nebulised at different positions in the circuit and separately, with no ventilator. The amount of salbutamol contained in various particle size fractions was also determined. Nebuliser position within the NIV circuit was critically important for drug delivery. Optimal delivery of salbutamol occurred with the expiration port between the facemask and nebuliser (647+/-67 micro g). This was significantly better than nebulisation without the ventilator (424+/-61 micro g; P < 0.01). Delivery when the nebuliser was positioned between the facemask and expiration port was 544+/-85 micro g. The amount of salbutamol contained in particles < 5 micro m was significantly increased when the nebuliser was used in conjunction with bi-level ventilation (576+/-60 micro g vs 300+/-43 micro g, P < 0.001). We conclude that nebulised bronchodilator therapy, using a Cirrus jet nebuliser, during bi-level ventilation increases respirable particles likely to be inhaled when the nebuliser is optimally positioned within the circuit.

Для цитирования: Calvert Lori D, Jackson Judith M, White Judy A, Barry Peter W, Kinnear William J, O'Callaghan Christopher. Enhanced delivery of nebulised salbutamol during non-invasive ventilation.. The Journal of pharmacy and pharmacology. 2006. DOI: 10.1211/jpp.58.11.0017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.