BACKGROUND

In low-gradient severe aortic stenosis (AS), reduced left ventricular ejection fraction (LVEF <50%) is practically used to define low flow and prompt dobutamine stress echocardiography to discern pseudo-severe AS. In patients with preserved LVEF, stroke volume index (SVI) <35 mL/m² is typically used. However, both are volume-based surrogates. Transaortic flow rate (TAFR), calculated as stroke volume divided by left ventricular ejection time, may better reflect true flow. Nonetheless, comparative data between TAFR and established metrics remain limited. We aimed to evaluate the prognostic value of TAFR in symptomatic low-gradient severe AS.

METHODS

We retrospectively identified patients with low-gradient severe AS (AVA ≤1 cm2 and peak velocity (Vmax) <4 m/s or mean gradient (MG) <40 mm Hg) who underwent transcatheter aortic valve replacement at Mayo Clinic sites (2017-2023). The primary outcome was 1-year all-cause mortality. Survival was assessed using Kaplan-Meier and Cox proportional hazards models.

RESULTS

Among 475 patients included (mean age 85±8 years; 49% women), 242 (51%) had TAFR <220 mL/s, 165 (35%) had EF <50%, and 221 (47%) had SVI <35 mL/m2. Low TAFR was significantly associated with higher 1-year mortality even after stratifying by EF or SVI. In multivariate analysis, TAFR was an independent predictor of mortality (HR 2.38; 95% CI 1.19 to 4.76, p=0.014) after adjusting for reduced LVEF, low SVI, gender, chronic kidney disease and mitral and tricuspid regurgitation.

CONCLUSIONS

In patients with symptomatic low-gradient severe AS, low TAFR, not SVI or LVEF, is independently associated with mortality and may offer more accurate measure of flow state for clinical staging.

Для цитирования: Allam Mohamed, Villa Etchegoyen Cecilia, Alsidawi Said, Pathangey Girish, Sheashaa Hesham, Rafie Nikita, Ibrahim Ramzi, Farina Juan M, Mahmoud Ahmed K, Awad Kamal, Abdelnabi Mahmoud, Sell-Dottin Kristen, Lester Steven J, Sweeney John P, Ayoub Chadi, Lee Kwan, Fortuin David F, Arsanjani Reza. Prognostic value of transaortic flow rate compared with ejection fraction and stroke volume index in low-gradient severe aortic stenosis.. Heart (British Cardiac Society). 2026. DOI: 10.1136/heartjnl-2025-327594.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.