MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bmjopen-2023-076193

Медицинская библиотека · BMJ open · 2023

Sensitivity and specificity of the Patient Health Questionnaire (PHQ-9, PHQ-8, PHQ-2) and General Anxiety Disorder scale (GAD-7, GAD-2) for depression and anxiety diagnosis: a cross-sectional study in a Peruvian hospital population.

Villarreal-Zegarra David, Barrera-Begazo Juan, Otazú-Alfaro Sharlyn, Mayo-Puchoc Nikol, Bazo-Alvarez Juan Carlos, Huarcaya-Victoria Jeff

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

The Patient Health Questionnaire (PHQ) and Generalised Anxiety Disorder Scale (GAD) are widely used screening tools, but their sensitivity and specificity in low-income and middle-income countries are lower than in high-income countries. We conducted a study to determine the sensitivity and specificity of different versions of these scales in a Peruvian hospital population.

DESIGN

Our study has a cross-sectional design.

SETTING

Our participants are hospitalised patients in a Peruvian hospital. The gold standard was a clinical psychiatric interview following ICD-10 criteria for depression (F32.0, F32.1, F32.2 and F32.3) and anxiety (F41.0 and F41.1).

PARTICIPANTS

The sample included 1347 participants. A total of 334 participants (24.8%) were diagnosed with depression, and 28 participants (2.1%) were diagnosed with anxiety.

RESULTS

The PHQ-9's≥7 cut-off point showed the highest simultaneous sensitivity and specificity when contrasted against a psychiatric diagnosis of depression. For a similar contrast against the gold standard, the other optimal cut-off points were: ≥7 for the PHQ-8 and ≥2 for the PHQ-2. In particular, the cut-off point ≥8 had good performance for GAD-7 with sensitivity and specificity, and cut-off point ≥10 had lower levels of sensitivity, but higher levels of specificity, compared with the cut-off point of ≥8. Also, we present the sensitivity and specificity values of each cut-off point in PHQ-9, PHQ-8, PHQ-2, GAD-7 and GAD-2. We confirmed the adequacy of a one-dimensional model for the PHQ-9, PHQ-8 and GAD-7, while all PHQ and GAD scales showed good reliability.

CONCLUSIONS

The PHQ and GAD have adequate measurement properties in their different versions. We present specific cut-offs for each version.

Для цитирования: Villarreal-Zegarra David, Barrera-Begazo Juan, Otazú-Alfaro Sharlyn, Mayo-Puchoc Nikol, Bazo-Alvarez Juan Carlos, Huarcaya-Victoria Jeff. Sensitivity and specificity of the Patient Health Questionnaire (PHQ-9, PHQ-8, PHQ-2) and General Anxiety Disorder scale (GAD-7, GAD-2) for depression and anxiety diagnosis: a cross-sectional study in a Peruvian hospital population.. BMJ open. 2023. DOI: 10.1136/bmjopen-2023-076193.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.