BACKGROUND

It remains controversial whether prosthesis-patient mismatch (PPM) (in general considered moderate if indexed effective orifice area is 0.65-0.85 cm2/m2 and severe when <0.65 cm2/m2) affects the outcomes after transcatheter aortic valve replacement (TAVR).

OBJECTIVES

The purpose of this study is to evaluate the time-varying effects and association of PPM with the risk of overall mortality.

METHODS

Study-level meta-analysis of reconstructed time-to-event data from Kaplan-Meier curves of studies published by December 30, 2021.

RESULTS

In total, 23 studies met our eligibility criteria and included a total of 81,969 patients included in the Kaplan-Meier curves (19,612 with PPM and 62,357 without PPM). Patients with moderate/severe PPM had a significantly higher risk of mortality compared with those without PPM (HR: 1.09 [95% CI: 1.04-1.14]; P < 0.001). In the first 30 months after the procedure, mortality rates were significantly higher in the moderate/severe PPM group (HR: 1.1 [95% CI: 1.05-1.16]; P < 0.001). In contrast, the landmark analysis beyond 30 months yielded a reversal of the HR (0.83 [95% CI: 0.68-1.01]; P = 0.064), but without statistical significance. In the sensitivity analysis, although the authors observed that severe PPM showed higher risk of mortality in comparison with no PPM (HR: 1.25 [95% CI: 1.16-1.36]; P < 0.001), they did not observe a statistically significant difference for mortality between moderate PPM and no PPM (HR: 1.03 [95% CI: 0.96-1.10]; P = 0.398).

CONCLUSIONS

Severe PPM, but not moderate PPM, was associated with higher risk of mortality following TAVR. These results provide support to implementation of preventive strategies to avoid severe PPM following TAVR.

Для цитирования: Sá Michel Pompeu, Jacquemyn Xander, Van den Eynde Jef, Tasoudis Panagiotis, Dokollari Aleksander, Torregrossa Gianluca, Sicouri Serge, Clavel Marie-Annick, Pibarot Philippe, Ramlawi Basel. Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement: Meta-Analysis of Kaplan-Meier-Derived Individual Patient Data.. JACC. Cardiovascular imaging. 2022. DOI: 10.1016/j.jcmg.2022.07.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.