m+Medelevator.RU
← Поиск публикаций
Heart, lung & circulation · 2022

Long-Term Valve Durability in Patients Undergoing Transcatheter Aortic Valve Implantation.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Stehli Julia, Dagan Misha, Duffy Stephen J, Morisset Stéphane, Vriesendorp Pieter, Nanayakkara Shane, Samuel Koh Ji Quan, Quine Edward, Htun Nay M, Stub Dion, Dick Ron, Walton Antony S

Аннотация

AIMS: To evaluate the long-term incidence of structural valve deterioration (SVD) in patients who underwent transcatheter aortic valve implantation (TAVI).

METHOD AND RESULTS: Between 2008 and 2018, 693 underwent TAVI at two centres. Four hundred and twenty-one (421) patients (mean age 83.6±6.0 yrs) survived for ≥2 years post TAVI and had at least two consecutive transthoracic echocardiographies (TTEs) with the latest TTE no less than 2 years after TAVI, and were therefore included in the analysis for SVD. Median follow-up was 4.7 (3.6-6.0) years and median echocardiography follow-up 3 (3.0-4.0) years. All-cause mortality was 30.9% (130) with a median time to death of 4.1 (3.0-5.6) years. The cumulative incidence of SVD increased from 1.7% (95% CI, 0.4-2.9) at 3 years to 3.5% (95% CI, 1.5-5.8) at 5 years and 4.7% (95% CI, 1.6-7.9) at 10 years. The overall median time to SVD was 3 (2-4) years. Twelve (12) patients demonstrated SVD stage 2, and 1 patient stage 3. No SVD required re-intervention. All other patients showed no significant changes in valve parameters over time.

CONCLUSIONS: Structural valve deterioration is an uncommon event, occurring in 5% over a total follow-up of 10 years. Most patients show stable valve parameters. However, the analysis is limited by the loss of follow-up (owing to patient mortality), which renders extrapolation of the data to a younger patient population difficult.