Application of a Novel Two-Dimensional Echocardiographic Calcium Quantification Method to Assess All Severities of Aortic Stenosis.

Desai Kevin, Slostad Brody, Twing Aamir, Krishna Hema, Frazin Leon, Kansal Mayank

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Aortic valve (AV) calcification (AVC) is a strong predictor of aortic stenosis (AS) severity. The two-dimensional AVC (2D-AVC) ratio, a gain-independent ratio composed of the average pixel density of the AV and the aortic annulus, has previously shown strong correlations with two-dimensional (2D) echocardiographic hemodynamic parameters for severe AS and AVC by cardiac computed tomography. We hypothesize that the 2D-AVC ratio correlates with hemodynamic parameters in all severities of AS.

METHODS

A total of 285 patients with a normal AV (n = 49), aortic sclerosis (n = 75), or mild (n = 38), moderate (n = 72), or severe (n = 51) AS undergoing 2D echocardiography were retrospectively evaluated, and the 2D-AVC ratios were correlated to mean AV gradient, peak AV velocity, AV area, and dimensionless index. The 2D-AVC ratios of various AS severities were compared against each other via area under the curve (AUC) analysis.

RESULTS

The 2D-AVC ratio is strongly correlated with mean AV gradient (r = 0.79, P < .0001) and peak AV velocity (r = 0.78, P < .0001). There was moderate correlation with the AV area (r = -0.58, P < .0001) and dimensionless index (r = -0.67, P < .0001) across all AS severities. The 2D-AVC ratio also distinguished nonmoderate AS (mild AS + normal AV) from moderate or greater (moderate + severe) AS (AUC = 0.93) and moderate versus severe AS (AUC = 0.88).

CONCLUSION

The 2D-AVC ratio exhibits moderate to strong correlation with 2D echocardiographic hemodynamic parameters across all severities of AS.

Для цитирования: Desai Kevin, Slostad Brody, Twing Aamir, Krishna Hema, Frazin Leon, Kansal Mayank. Application of a Novel Two-Dimensional Echocardiographic Calcium Quantification Method to Assess All Severities of Aortic Stenosis.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2022. DOI: 10.1016/j.echo.2022.10.023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.