Long-term outcomes of balloon-expandable transcatheter aortic valve replacement in Japanese patients.

Fuku Yasushi, Goto Tsuyoshi, Ikuta Akihiro, Ohya Masanobu, Maruo Takeshi, Komiya Tatsuhiko, Kadota Kazushige

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Data on long-term outcomes of transcatheter aortic valve replacement (TAVR) in Japanese patients beyond 5 years are limited.

METHODS

Between June 2010 and December 2014, 55 consecutive inoperable or high surgical risk patients underwent TAVR with SAPIEN XT valves (Edwards Lifesciences, Irvine, CA, USA) for severe aortic stenosis at our institution. Among them, 2 patients were excluded from the analysis because one was converted to open surgery during the TAVR procedure and the other could not undergo TAVR due to device delivery failure. We retrospectively analyzed long-term clinical outcomes of these 53 patients (mean age: 84.1 years; mean STS score: 8.4) who had at least a 7-year follow-up after TAVR.

RESULTS

The rates of freedom from all-cause and cardiovascular deaths at 7 years were 35.8 % and 79.3 %, respectively. The moderate or severe structural valve deterioration (SVD) rate at 5 and 7 years was 7.2 % and 11.4 %, respectively. The rate of bioprosthetic valve failure (BVF) at 7 years was 6.2 %.

CONCLUSIONS

The 7-year mortality rate of inoperable or high surgical risk patients treated with SAPIEN XT was high, while the cardiovascular mortality rate was acceptable. Although the poor survival rate limited the long-term assessment of SAPIEN XT valve durability, the incidence of SVD and BVF was not rare.

Для цитирования: Fuku Yasushi, Goto Tsuyoshi, Ikuta Akihiro, Ohya Masanobu, Maruo Takeshi, Komiya Tatsuhiko, Kadota Kazushige. Long-term outcomes of balloon-expandable transcatheter aortic valve replacement in Japanese patients.. Journal of cardiology. 2022. DOI: 10.1016/j.jjcc.2022.09.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.