JACC. Cardiovascular interventions · 2022
Transvalvular Pressure Gradients and All-Cause Mortality Following TAVR: A Multicenter Echocardiographic and Invasive Registry.
СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Khalili Houman, Pibarot Philippe, Hahn Rebecca T, Elmariah Sammy, Pilgrim Thomas, Bavry Anthony A, Maini Brijeshwar, Okuno Taishi, Al-Azizi Karim, Waggoner Thomas E, Mack Michael, Rodès-Cabau Joseph, Abbas Amr E
Аннотация
BACKGROUND: Low ejection fraction (EF) and low flow as determined by an echocardiographic stroke volume index (SVi) <35 mL/m2 are associated with low transvalvular gradients and increased mortality in both severe aortic stenosis (AS) and post-transcatheter aortic valve replacement (TAVR). Absence of an elevated echocardiographic transaortic gradient post-TAVR is considered a marker of procedural success despite the absence of data on its impact on mortality.
OBJECTIVES: The authors sought to examine the association of invasive and echocardiographic gradients post-TAVR with all-cause mortality in relation to flow and EF.
METHODS: In a multicenter retrospective registry of patients undergoing TAVR, Cox models with regression splines explored the relationship between invasive and echocardiographic gradients post-TAVR with 2-year mortality. An invasive gradient <5 mm Hg was considered low, between ≥5 and <10 mm Hg was considered intermediate, and ≥10 mm Hg was considered high. An echocardiographic gradient <10 mm Hg was considered low, ≥10 and <20 mm Hg was considered intermediate, and ≥20 mm Hg was considered high.
RESULTS: Higher mortality occurred in low echocardiographic gradients at discharge relative to intermediate gradients (P < 0.001), and low gradient was associated with lower EF and echocardiographic SVi (P < 0.001 and P < 0.008, respectively). Lower mortality occurred in low invasive gradients relative to intermediate gradients (P = 0.012) with no difference in EF and echocardiographic SVi between groups (P = 0.089 and P = 0.947, respectively). There were insufficient observations to determine the impact of high echocardiographic and invasive gradients on mortality.
CONCLUSIONS: In this large retrospective analysis, the impact of transaortic gradients on mortality after TAVR was not linear and complex, showing opposite results among echocardiographic and invasive measurements in low-gradient patients.
OBJECTIVES: The authors sought to examine the association of invasive and echocardiographic gradients post-TAVR with all-cause mortality in relation to flow and EF.
METHODS: In a multicenter retrospective registry of patients undergoing TAVR, Cox models with regression splines explored the relationship between invasive and echocardiographic gradients post-TAVR with 2-year mortality. An invasive gradient <5 mm Hg was considered low, between ≥5 and <10 mm Hg was considered intermediate, and ≥10 mm Hg was considered high. An echocardiographic gradient <10 mm Hg was considered low, ≥10 and <20 mm Hg was considered intermediate, and ≥20 mm Hg was considered high.
RESULTS: Higher mortality occurred in low echocardiographic gradients at discharge relative to intermediate gradients (P < 0.001), and low gradient was associated with lower EF and echocardiographic SVi (P < 0.001 and P < 0.008, respectively). Lower mortality occurred in low invasive gradients relative to intermediate gradients (P = 0.012) with no difference in EF and echocardiographic SVi between groups (P = 0.089 and P = 0.947, respectively). There were insufficient observations to determine the impact of high echocardiographic and invasive gradients on mortality.
CONCLUSIONS: In this large retrospective analysis, the impact of transaortic gradients on mortality after TAVR was not linear and complex, showing opposite results among echocardiographic and invasive measurements in low-gradient patients.