MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0211064

Медицинская библиотека · PloS one · 2019

High-throughput analysis of insecticides on malaria vectors using liquid chromatography tandem mass spectrometry.

Spielmeyer Astrid, Schetelig Marc F, Etang Josiane

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Different setups and protocols have been developed for investigating insecticide effects on Anopheles (An.) mosquitoes, vectors of malaria. However, chemical uptake resulting from their tarsal contact with insecticide-treated material has seldom been investigated. To address the challenges encountered in the interpretation of bioassay data, a high throughput method for chemical analysis on malaria vectors was developed and validated for five selected insecticides including alpha-cypermethrin (aCYP), deltamethrin (DM), etofenprox (EPX), permethrin (PM), pirimiphos-methyl (PPM).

METHODS

The method includes a single chemical extraction step via an ultrasound probe on mosquito samples and analysis via liquid chromatography coupled to high-resolution tandem mass spectrometry (UHPLC-MS/MS). The protocol was established for two malaria vector species, Anopheles gambiae senso stricto (s.s.) and An. stephensi, both males and females. Recovery rates ranged from 70 to 100% without any influence of sex or species. The method was efficiently applied to female An. gambiae s.s. of the KISUMU1 reference strain, after susceptibility tests using the World Health Organization's standard protocol.

RESULTS

Susceptibility tests revealed 13.4-18.4 minutes knockdown times for 50% mosquitoes during exposure to EPX and pyrethroids. The mortality rates 24 hours post-exposure to insecticides were mostly 99-100%, except in two PM and three PPM assays suggesting possible or confirmed resistance to these insecticides. The mean insecticide uptake in dead mosquitoes ranged from 23 pg (aCYP) to 1812 pg (EPX) per specimen. However, the mean uptake in survivors to PM and PPM was reduced by at least 25%, suggesting that acute doses were not achieved in these specimens during bioassays.

CONCLUSIONS

The developed and validated UHPLC-MS/MS method could be used to address some limitations of bioassays or to assess the penetration of insecticides in mosquito matrix with reference to cuticle thickness and other insecticide resistance mechanisms.

Для цитирования: Spielmeyer Astrid, Schetelig Marc F, Etang Josiane. High-throughput analysis of insecticides on malaria vectors using liquid chromatography tandem mass spectrometry.. PloS one. 2019. DOI: 10.1371/journal.pone.0211064.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.