Comparative study of transepidermal water loss in patients with and without hyperhidrosis by closed-chamber measurer in an air-conditioned environment.

Miotto Andre, Honda Pedro Augusto Antunes, Bachichi Thiago Gangi, Holanda Caio Santos, Evangelista Neto Ernesto, Perfeito João Alessio Juliano, Leão Luiz Eduardo Villaça, Costa Altair da Silva

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the difference in transepidermal water loss in patients diagnosed with hyperhidrosis and healthy subjects, in an air-conditioned environment.

METHODS

Twenty patients diagnosed with hyperhidrosis and 20 healthy subjects were subjected to quantitative assessment using a closed-chamber device, in six previously established sites.

RESULTS

The measurements showed different transepidermal water loss values for healthy subjects and patients with hyperhidrosis, especially in the hands and feet. In the Control Group, the median for the hands was 46.4g/m2/hour (p25: 36.0; p75: 57.6), while in the Hyperhidrosis Group, the median was 123.5g/m2/hour (p25: 54.3; p75: 161.2) - p<0.001. For the feet, the Control Group had a median of 41.5g/m2/hour (p25: 31.3; p75: 63.5) and the Hyperhidrosis Group, 61.2g/m2/hour (p25: 32.3; p75: 117) - p<0.02. Measurements of the axillas also showed differences. In the Control Group, the median was 14.8g/m2/hour (p25: 11.8; p75: 19.0) and, in the Hyperhidrosis Group, 83.5g/m2/hour (p25: 29.5; p75: 161.7) - p<0.001.

CONCLUSION

Measuring transepidermal water loss is sufficient for diagnosis and follow-up of patients with hyperhidrosis.

Для цитирования: Miotto Andre, Honda Pedro Augusto Antunes, Bachichi Thiago Gangi, Holanda Caio Santos, Evangelista Neto Ernesto, Perfeito João Alessio Juliano, Leão Luiz Eduardo Villaça, Costa Altair da Silva. Comparative study of transepidermal water loss in patients with and without hyperhidrosis by closed-chamber measurer in an air-conditioned environment.. Einstein (Sao Paulo, Brazil). 2018. DOI: 10.31744/einstein_journal/2018ao4312.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.