Медицинская библиотека · American journal of respiratory and critical care medicine · 2006

Bronchoscopy in ventilator-associated pneumonia: agreement of calibrated loop and serial dilution.

Afessa Bekele, Hubmayr Rolf D, Vetter Emily A, Keegan Mark T, Swanson Karen L, Baddour Larry M, Cockerill Franklin R, Peters Steve G

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

RATIONALE: Although the serial dilution technique for quantitative culture of bronchoalveolar fluid is considered to be the gold standard for the diagnosis of ventilator-associated pneumonia, it is more labor intensive than the calibrated loop technique.

OBJECTIVE

We sought to determine the agreement between the calibrated loop and serial dilution techniques in the diagnosis of ventilator-associated pneumonia.

METHODS

We prospectively measured bacterial colony counts by the serial dilution and calibrated loop techniques in 121 bronchoalveolar lavage samples of 104 patients with suspected ventilator-associated pneumonia.

MEASUREMENTS AND MAIN

RESULTS

At the time of bronchoscopy, patients had received mechanical ventilation for a median of 8 d. Patients were receiving antibiotics when 90 of the 121 (74.4%) bronchoalveolar samples were obtained. The colony counts of 13 bacterial isolates were too numerous to count by the calibrated loop technique; by serial dilution technique, their counts ranged from 4.70 to 6.74 log10 cfu/ml. Fifty other bacteria had paired colony counts measured by each of the two techniques: the bias (95% confidence interval) between the two techniques was -0.380 (-0.665 to -0.095) log10 cfu/ml, with precision of 1.002 log10 cfu/ml and 95% limits of agreement of -2.344 to 1.584 log10 cfu/ml. Using the threshold of 4 log10 cfu/ml as a criterion for the diagnosis of ventilator-associated pneumonia, there was discordance only for one bacterial organism between the two techniques.

CONCLUSIONS

The calibrated loop technique can be used for the diagnosis of ventilator-associated pneumonia using bronchoalveolar lavage fluid.

Для цитирования: Afessa Bekele, Hubmayr Rolf D, Vetter Emily A, Keegan Mark T, Swanson Karen L, Baddour Larry M, Cockerill Franklin R, Peters Steve G. Bronchoscopy in ventilator-associated pneumonia: agreement of calibrated loop and serial dilution.. American journal of respiratory and critical care medicine. 2006. DOI: 10.1164/rccm.200512-1899oc.